EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the Efficacy of Different Mechanical Inter‐Dental Devices Around Single Implant Prosthetic Crowns: In Vitro Study

Lorenzo Bevilacqua iD, Simone Poncato, Antonietta Scarazzato, Silvia Filippini, Michele Maglione

International Journal of Dental Hygiene · 2026

DOI: 10.1111/idh.70013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Dental Hygiene, 2026. Verfasst von Lorenzo Bevilacqua und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Maxillofacial Surgery and Stomatology, Maggiore Hospital in Trieste, Trieste, Italy. Hauptthemen laut MEDLINE: Crowns, Dental Implants, Single-Tooth, Dental Plaque, Dental Prosthesis, Implant-Supported. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

The aim of the study was to analyse the effectiveness of some interproximal tools to remove bacterial biofilm on implant‐prosthesis rehabilitations with different morphological characteristics.

Methods

3 temporary crowns made by polymethylmethacrylate resin with different emergency profiles (20°, 30° and 40°) screwed onto an implant placed on a resin model at different implant depth relative to bone crest (bone level, subcresal at 1 mm, supracrestal at 1 mm). After coating surfaces with a contact detection spray, the screwed crowns were cleaned with different interproximal tools: the Oral‐B Super FlossTM, the TePe Bridges & Implant Floss, the cylindrical brush TePe Original, the conical brush GUM TRAV‐LER and the TePe EasyPickTM soft pick. At the end of each use the crowns were photographed and analysed using TextCompare software. For each tool, five measurements were taken per interproximal surface. The data were analysed statistically.

Results

All the tools were effective in reducing the interproximal plaque. Lower results were obtained by the TePe EasyPickTM soft pick (min‐max cleaned surface 47%–68%). In implant‐prosthesis with emergence angles below 30° the interproximal brushes were more efficient (cleaned area min‐max 74%–75%), while with greater angles implant floss was more effective (cleaned area min‐max 73%–76%).

Conclusion

Brushes for smaller emergence profiles and subcrestal implants and floss for crowns with larger emergence profiles and supracrestal implants are recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CrownsDental Implants, Single-ToothDental PlaqueDental Prosthesis, Implant-SupportedHumansIn Vitro TechniquesBiofilmsSurface Properties

Stichwörter der Autor:innen

dental flossemergence profileimplantinter‐dental brushesinter‐dental cleaningprosthetic crown

Autor:innen und Institutionen

  • Department of Maxillofacial Surgery and Stomatology, Maggiore Hospital in Trieste, Trieste, Italy.
  • Dental Hygiene, Trieste, Italy.

ORCID-Profile: Lorenzo Bevilacqua

Zitieren

APA

Bevilacqua, L., Poncato, S., Scarazzato, A., Filippini, S., & Maglione, M. (2026). Evaluation of the Efficacy of Different Mechanical Inter‐Dental Devices Around Single Implant Prosthetic Crowns: In Vitro Study. International Journal of Dental Hygiene. https://doi.org/10.1111/idh.70013

Vancouver

Bevilacqua L, Poncato S, Scarazzato A, Filippini S, Maglione M. Evaluation of the Efficacy of Different Mechanical Inter‐Dental Devices Around Single Implant Prosthetic Crowns: In Vitro Study. International Journal of Dental Hygiene. 2026. doi:10.1111/idh.70013

BibTeX
@article{Bevilacqua2026,
  author = {Bevilacqua, Lorenzo and Poncato, Simone and Scarazzato, Antonietta and Filippini, Silvia and Maglione, Michele},
  title = {Evaluation of the Efficacy of Different Mechanical Inter‐Dental Devices Around Single Implant Prosthetic Crowns: In Vitro Study},
  journal = {International Journal of Dental Hygiene},
  year = {2026},
  doi = {10.1111/idh.70013}
}
Kostenlos starten →