EUVIMEDOpdag EUVIMED
Crossref

Association Between Pulse Wave Velocity and Arteriovenous Fistula Stenosis in Hemodialysis Patients

Kai-Ni Lee, Chien-An Chen iD, Li-Yu Yang

Hemodialysis International · 2026

DOI: 10.1111/hdi.70001 ↗

At a glance

Journal article in Hemodialysis International, 2026. Written by Kai-Ni Lee and 2 co-authors. Institution: Department of Nephrology, Tainan Sinlau Hospital, Tainan, Taiwan. Major MEDLINE topics: Renal Dialysis, Pulse Wave Analysis, Arteriovenous Shunt, Surgical. 35 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Arteriovenous (AV) fistulas are widely used in hemodialysis patients, but their most common complication is stenosis. Stiffness at the arterial site of the AV fistula is believed to contribute to stenosis. This study examines whether arterial stiffness can predict the development of AV fistula stenosis.

Methods

Arterial stiffness was assessed using brachial‐ankle pulse wave velocity (PWV). Chart reviews and laboratory records were analyzed. The diagnosis and intervention for AV fistula stenosis were performed using fistulography and percutaneous transluminal angioplasty.

Findings

A total of 80 patients were enrolled in the study. Over the 7‐year follow‐up period, 40 patients developed AV fistula stenosis. Univariate logistic regression analysis revealed that AV fistula stenosis was significantly associated with diabetes ( OR : 4.68, 95% CI : 1.19–18.34, p = 0.03), average monthly cholesterol level ( OR : 1.02, 95% CI : 1.00–1.04, p = 0.03), average monthly triglyceride level ( OR : 1.01, 95% CI : 1.00–1.01, p = 0.02), and brachial‐ankle PWV ( OR : 1.61, 95% CI : 1.32–1.97, p < 0.01). In multivariate logistic regression analysis, only brachial‐ankle PWV remained significantly associated with AV fistula stenosis ( OR : 1.72, 95% CI : 1.34–2.22, p < 0.01). Receiver‐operating characteristic curve analysis identified 16.75 m/s as the optimal cutoff value of brachial‐ankle PWV for predicting the development of AV fistula stenosis. Patients with PWV > 16.75 m/s had a significantly higher risk of developing AV fistula stenosis compared with those with a PWV ≤ 16.75 m/s ( HR : 4.71, 95% CI : 2.22–9.97, p < 0.01).

Discussion

Assessment of brachial‐ankle PWV can improve the prediction efficacy of AV fistula stenosis development in hemodialysis patients.

Subjects

MeSH terms (MEDLINE)

Renal DialysisPulse Wave AnalysisArteriovenous Shunt, SurgicalHumansMaleFemaleMiddle AgedConstriction, PathologicAgedVascular Stiffness

Author keywords

AV fistula stenosisarterial stiffnessbrachial‐ankle PWV

Authors and institutions

  • Department of Nephrology, Tainan Sinlau Hospital, Tainan, Taiwan.
  • Graduate Institute of Nursing, College of Nursing, Kaohsiung Medical University, Kaohsiung, Taiwan.

ORCID profiles: Chien-An Chen

Cite

APA

Lee, K. N., Chen, C. A., & Yang, L. Y. (2026). Association Between Pulse Wave Velocity and Arteriovenous Fistula Stenosis in Hemodialysis Patients. Hemodialysis International. https://doi.org/10.1111/hdi.70001

Vancouver

Lee KN, Chen CA, Yang LY. Association Between Pulse Wave Velocity and Arteriovenous Fistula Stenosis in Hemodialysis Patients. Hemodialysis International. 2026. doi:10.1111/hdi.70001

BibTeX
@article{Lee2026,
  author = {Lee, Kai-Ni and Chen, Chien-An and Yang, Li-Yu},
  title = {Association Between Pulse Wave Velocity and Arteriovenous Fistula Stenosis in Hemodialysis Patients},
  journal = {Hemodialysis International},
  year = {2026},
  doi = {10.1111/hdi.70001}
}
Start for free →