Screening for subclinical synovial proliferation in haemophilia: A systematic review and meta‐analysis comparing physical examination and ultrasound
Haemophilia · 2023-03 · 29 (2) · 445-455
DOI: 10.1111/hae.14737 ↗At a glance
Metaanalyse in Haemophilia, published online on 2023-01-03. Written by Flora H P van Leeuwen and 4 co-authors. Institution: Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands. Major MEDLINE topics: Hemophilia A, Joint Diseases. Cited 12 times so far (Crossref); 51 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Swedish Orphan Biovitrum.
Abstract (original language)
Introduction
Ultrasound is increasingly used as addition to physical examination for detection of subclinical joint changes in haemophilia. However, the added value of ultrasound to physical examination for detecting synovial proliferation is not fully established.
Aim
To determine the diagnostic accuracy of swelling at physical examination for ultrasound‐detected synovial proliferation in haemophilia.
Methods
PubMed and EMBASE were searched up to 2 August 2022. Studies reporting original data on occurrence of swelling at physical examination and synovial proliferation on ultrasound of index joints in persons with haemophilia were included. Risk of bias and applicability were assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS‐2) tool. Diagnostic accuracy parameters of swelling at physical examination for ultrasound‐detected synovial proliferation were determined. Summary sensitivity and specificity were calculated using a bivariate random‐effects model.
Results
Fifteen studies reporting on swelling at physical examination and synovial proliferation on ultrasound in 2890 joints of 627 patients were included. Prevalence of subclinical synovial proliferation ranged between 0% and 55%. Sensitivity of swelling was low [summary estimate .34; 95% confidence interval (CI) .24‐.46], while specificity was high (summary estimate .97; CI .92‐.99). Predictive values varied widely due to inter‐study differences in prevalence of synovial proliferation.
Conclusion
Joint swelling has low sensitivity for presence of ultrasound‐detected synovial proliferation in haemophilia, suggesting underestimation of synovial proliferation by physical examination alone. Consequently, ultrasound screening may generate important information on synovial changes which would otherwise remain undetected.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
- Center for Benign Hematology, Thrombosis and Haemostasis, Van Creveldkliniek, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
ORCID profiles: Flora H P van Leeuwen, Merel A Timmer, Kathelijn Fischer, Wouter Foppen
Funding
- Swedish Orphan Biovitrum
Cite
APA
van Leeuwen, F. H. P., Timmer, M. A., de Jong, P. A., Fischer, K., & Foppen, W. (2023). Screening for subclinical synovial proliferation in haemophilia: A systematic review and meta‐analysis comparing physical examination and ultrasound. Haemophilia, 29(2), 445-455. https://doi.org/10.1111/hae.14737
Vancouver
van Leeuwen FHP, Timmer MA, de Jong PA, Fischer K, Foppen W. Screening for subclinical synovial proliferation in haemophilia: A systematic review and meta‐analysis comparing physical examination and ultrasound. Haemophilia. 2023;29(2):445-455. doi:10.1111/hae.14737
BibTeX
@article{vanLeeuwen2023,
author = {van Leeuwen, Flora H P and Timmer, Merel A and de Jong, Pim A and Fischer, Kathelijn and Foppen, Wouter},
title = {Screening for subclinical synovial proliferation in haemophilia: A systematic review and meta‐analysis comparing physical examination and ultrasound},
journal = {Haemophilia},
year = {2023},
volume = {29},
number = {2},
pages = {445--455},
doi = {10.1111/hae.14737}
}
EUVIMED