Bisphenol A release from CAD/CAM splint materials
European Journal of Oral Sciences · 2024
DOI: 10.1111/eos.12993 ↗At a glance
Journal article in European Journal of Oral Sciences, 2024. Written by Tristan Hampe and 4 co-authors. Institution: Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany. Major MEDLINE topics: Benzhydryl Compounds, Phenols, Computer-Aided Design. Cited 3 times so far (Crossref); 67 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: German Society of Dentistry and Oral Medicine (DGZMK).
Abstract (original language)
This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate‐based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate‐based (Temp Basic) material. From each material, ten cylindrical samples ( n = 40) were immersed in high‐performance liquid chromatography (HPLC) grade water following ISO 10993‐12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material‐dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32–6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany.
- Department of Orthodontics, University Medical Center Göttingen, Göttingen, Germany.
- Department of Orthodontics, University Hospital Regensburg, Regensburg, Germany.
ORCID profiles: Tristan Hampe, Julia Liersch, Bernhard Wiechens, Ralf Bürgers, Sebastian Krohn
Funding
- German Society of Dentistry and Oral Medicine (DGZMK)
Cite
APA
Hampe, T., Liersch, J., Wiechens, B., Bürgers, R., & Krohn, S. (2024). Bisphenol A release from CAD/CAM splint materials. European Journal of Oral Sciences. https://doi.org/10.1111/eos.12993
Vancouver
Hampe T, Liersch J, Wiechens B, Bürgers R, Krohn S. Bisphenol A release from CAD/CAM splint materials. European Journal of Oral Sciences. 2024. doi:10.1111/eos.12993
BibTeX
@article{Hampe2024,
author = {Hampe, Tristan and Liersch, Julia and Wiechens, Bernhard and Bürgers, Ralf and Krohn, Sebastian},
title = {Bisphenol A release from CAD/CAM splint materials},
journal = {European Journal of Oral Sciences},
year = {2024},
doi = {10.1111/eos.12993}
}
EUVIMED