EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Bisphenol A release from CAD/CAM splint materials

Tristan Hampe iD, Julia Liersch iD, Bernhard Wiechens iD, Ralf Bürgers iD, Sebastian Krohn iD

European Journal of Oral Sciences · 2024

DOI: 10.1111/eos.12993 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Oral Sciences, 2024. Verfasst von Tristan Hampe und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany. Hauptthemen laut MEDLINE: Benzhydryl Compounds, Phenols, Computer-Aided Design. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: German Society of Dentistry and Oral Medicine (DGZMK).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate‐based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate‐based (Temp Basic) material. From each material, ten cylindrical samples ( n = 40) were immersed in high‐performance liquid chromatography (HPLC) grade water following ISO 10993‐12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material‐dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32–6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Benzhydryl CompoundsPhenolsComputer-Aided DesignChromatography, High Pressure LiquidPolycarboxylate CementPolymethyl MethacrylateTandem Mass SpectrometryMaterials TestingSplintsDental MaterialsHumansBisphenol A Compounds

Stichwörter der Autor:innen

dental materialsendocrine disruptorpolycarbonatepolymethylmethacrylate

Substanzen

Benzhydryl CompoundsPhenolsPolycarboxylate CementPolymethyl MethacrylateDental Materialsbisphenol ABisphenol A Compoundspolycarbonate

Autor:innen und Institutionen

  • Department of Prosthodontics, University Medical Center Göttingen, Göttingen, Germany.
  • Department of Orthodontics, University Medical Center Göttingen, Göttingen, Germany.
  • Department of Orthodontics, University Hospital Regensburg, Regensburg, Germany.

ORCID-Profile: Tristan Hampe, Julia Liersch, Bernhard Wiechens, Ralf Bürgers, Sebastian Krohn

Förderung

  • German Society of Dentistry and Oral Medicine (DGZMK)

Zitieren

APA

Hampe, T., Liersch, J., Wiechens, B., Bürgers, R., & Krohn, S. (2024). Bisphenol A release from CAD/CAM splint materials. European Journal of Oral Sciences. https://doi.org/10.1111/eos.12993

Vancouver

Hampe T, Liersch J, Wiechens B, Bürgers R, Krohn S. Bisphenol A release from CAD/CAM splint materials. European Journal of Oral Sciences. 2024. doi:10.1111/eos.12993

BibTeX
@article{Hampe2024,
  author = {Hampe, Tristan and Liersch, Julia and Wiechens, Bernhard and Bürgers, Ralf and Krohn, Sebastian},
  title = {Bisphenol A release from CAD/CAM splint materials},
  journal = {European Journal of Oral Sciences},
  year = {2024},
  doi = {10.1111/eos.12993}
}
Kostenlos starten →