EUVIMEDOpdag EUVIMED
Multizentrische StudieOpen access · CC BY-NC 4.0

Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study

Young Gi Min iD, Zeinab Rajabally, Woohee Ju iD, Jiwon Lee, Jiwon Choi, Niraj Mistry, Seok-Jin Choi, Sung-Min Kim, Yoon-Ho Hong, Yusuf A Rajabally iD, Jung-Joon Sung

European Journal of Neurology · 2025

DOI: 10.1111/ene.70335 ↗

At a glance

Multizentrische Studie in European Journal of Neurology, 2025. Written by Young Gi Min and 10 co-authors. Institution: Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea. Major MEDLINE topics: Polyradiculoneuropathy, Chronic Inflammatory Demyelinating, Hand Strength, Minimal Clinically Important Difference, Muscle Strength Dynamometer. Cited 6 times so far (Crossref); 20 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: National Research Foundation of Korea.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction/Aim Grip strength (GS) is widely used in chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). Current guidelines recommend a 10% relative change as the minimal clinically important difference (MCID) to determine response to treatment, preferably based on the average of three consecutive daily measurements. However, appropriate thresholds remain unclear for identifying deterioration and for situations where daily monitoring is not feasible.

Methods

We analyzed 350 GS assessments from 122 CIDP patients across 2 neuromuscular centers in Korea and the UK. Clinical changes were classified as improved, deteriorated, or stable based on the patient's perception of change and validated outcome measures: Inflammatory Neuropathy Cause and Treatment (Korea), Overall Neuropathy Limitation Scale (UK), and Inflammatory Rasch‐built Overall Disability Scale (both sites). The Youden index was used to determine optimal MCID thresholds for absolute (kg) and relative (%) changes for improvement and deterioration, respectively. The performance of derived cut‐offs was compared with previously proposed thresholds.

Results

The guideline‐recommended 10% relative threshold showed notably low specificity and accuracy despite high sensitivity for both improvement and deterioration. Our derived thresholds, 5 kg for improvement, 4.5 kg for deterioration, and 20% for either direction of change, offered significantly higher specificity and accuracy.

Conclusion

Our findings highlight the need for more stringent thresholds than current recommendations when assessing patients based on single‐day measurements. Our proposed thresholds, double in amplitude of the currently guideline‐recommended relative value but close to that previously derived for the absolute cut‐off, offer improved diagnostic specificity, which may ensure more reliable monitoring in routine care.

Subjects

MeSH terms (MEDLINE)

Polyradiculoneuropathy, Chronic Inflammatory DemyelinatingHand StrengthMinimal Clinically Important DifferenceMuscle Strength DynamometerHumansMaleFemaleMiddle AgedRepublic of KoreaAgedUnited KingdomAdultDisability Evaluation

Author keywords

CIDPJamar dynamometerMCIDgrip strengthoutcome measure

Authors and institutions

  • Department of Neurology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Department of Neurology, University Hospitals Birmingham, Birmingham, UK.
  • Department of Neurology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Republic of Korea.
  • Department of Neurology, Seoul National University Hospital, Seoul, Republic of Korea.
  • Department of Neurology, Seoul National Boramae Medical Center, Seoul National University College of Medicine, Seoul, Republic of Korea.
  • Aston Medical School, Aston University, Birmingham, United Kingdom.

ORCID profiles: Young Gi Min, Woohee Ju, Yusuf A Rajabally

Funding

  • National Research Foundation of Korea

Cite

APA

Min, Y. G., Rajabally, Z., Ju, W., Lee, J., Choi, J., Mistry, N., Choi, S. J., Kim, S. M., Hong, Y. H., Rajabally, Y. A., & Sung, J. J. (2025). Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study. European Journal of Neurology. https://doi.org/10.1111/ene.70335

Vancouver

Min YG, Rajabally Z, Ju W, Lee J, Choi J, Mistry N, et al. Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study. European Journal of Neurology. 2025. doi:10.1111/ene.70335

BibTeX
@article{Min2025,
  author = {Min, Young Gi and Rajabally, Zeinab and Ju, Woohee and Lee, Jiwon and Choi, Jiwon and Mistry, Niraj and Choi, Seok-Jin and Kim, Sung-Min and Hong, Yoon-Ho and Rajabally, Yusuf A and Sung, Jung-Joon},
  title = {Minimal Clinically Important Difference for the Jamar Hand Grip Dynamometer in CIDP: A Korea‐UK Study},
  journal = {European Journal of Neurology},
  year = {2025},
  doi = {10.1111/ene.70335}
}
Start for free →