EUVIMEDOpdag EUVIMED
Klinische StudieOpen access · CC BY-NC-ND 4.0

Efficacy and safety of the implantable, magnetic resonance imaging‐compatible StimRouter neuromodulation system in the treatment of refractory lower urinary tract symptoms in multiple sclerosis patients

Rosaria Sacco iD, Paolo Maino, Eva Koetsier, Giulio Disanto iD, Julien Renard, Alex Digesu, Claudio Gobbi iD, Chiara Zecca iD

European Journal of Neurology · 2024

DOI: 10.1111/ene.16146 ↗

At a glance

Klinische Studie in European Journal of Neurology, 2024. Written by Rosaria Sacco and 7 co-authors. Institution: Department of Neurology, Multiple Sclerosis Center, Neurocenter of Southern Switzerland, Regional Hospital (EOC) of Lugano, Lugano, Switzerland. Major MEDLINE topics: Lower Urinary Tract Symptoms, Multiple Sclerosis, Urinary Bladder, Neurogenic, Urinary Bladder, Overactive. Cited 7 times so far (Crossref); 11 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Research Advisory Board of Ente Ospedaliero Cantonale (EOC), the Swiss Multiple Sclerosis Society.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background and purpose Lower urinary tract symptoms (LUTS) significantly affect quality of life (QoL) of multiple sclerosis (MS) patients, and pharmacotherapy has limited efficacy. We investigated efficacy and safety of the implantable StimRouter neuromodulation system for treating refractory LUTS in MS.

Methods

This prospective, single‐center, clinical trial was conducted at the Multiple Sclerosis Center of Lugano, Switzerland, involving MS patients treated with self‐administered percutaneous tibial nerve stimulation delivered by StimRouter over 24 weeks. Changes in video‐urodynamic parameters as well as LUTS severity were measured by Overactive Bladder Questionnaire (OAB‐q), QoL using the Multiple Sclerosis Quality of Life (MSQoL‐54), and treatment satisfaction using a 1–10 visual analogue scale. Adverse events were also recorded.

Results

Of 23 MS patients recruited, six had neurogenic detrusor overactivity (NDO), five had detrusor sphincter dyssynergia (DSD), and 12 had both NDO and DSD. Of patients with NDO, median bladder volume at first uninhibited contraction significantly increased from baseline to week 24 (median = 136 mL, interquartile range [IQR] = 101–244 mL vs. 343 mL, IQR = 237–391 mL; β = 138.2, p = 0.001). No significant changes of urodynamic parameters were found in patients with DSD. OAB‐q symptom scores progressively decreased, and OAB‐q quality of life scores increased ( β = −0.50, p < 0.001 and β = 0.47, p < 0.001, respectively), whereas MSQoL‐54 scores did not significantly change ( β = 0.24, p = 0.084) in the overall population. Treatment satisfaction was overall high (median = 8, IQR = 6–9). No serious adverse events were recorded.

Conclusions

StimRouter represents a minimally invasive, magnetic resonance imaging‐compatible, self‐administered neuromodulation device leading to objective and subjective improvements of OAB symptoms and related QoL in MS patients with refractory LUTS.

Subjects

MeSH terms (MEDLINE)

Lower Urinary Tract SymptomsMultiple SclerosisUrinary Bladder, NeurogenicUrinary Bladder, OveractiveHumansProspective StudiesQuality of LifeTreatment OutcomeUrodynamics

Author keywords

StimRouter neuromodulationdetrusor sphincter dyssynergialower urinary tract symptomsmultiple sclerosisneurogenic detrusor overactivity

Authors and institutions

  • Department of Neurology, Multiple Sclerosis Center, Neurocenter of Southern Switzerland, Regional Hospital (EOC) of Lugano, Lugano, Switzerland.
  • Anestesiologia, Neurocenter of Southern Switzerland, Regional Hospital (EOC) of Lugano, Lugano, Switzerland.
  • Faculty of Biomedical Sciences, Università della Svizzera Italiana (USI), Lugano, Switzerland.
  • Urology Service, Ospedale Regionale di Bellinzona e Valli (EOC), Bellinzona, Switzerland.
  • Department of Urogynaecology, Imperial College Healthcare NHS Trust, London, UK.

ORCID profiles: Rosaria Sacco, Giulio Disanto, Claudio Gobbi, Chiara Zecca

Funding

  • Research Advisory Board of Ente Ospedaliero Cantonale (EOC)
  • the Swiss Multiple Sclerosis Society

Cite

APA

Sacco, R., Maino, P., Koetsier, E., Disanto, G., Renard, J., Digesu, A., Gobbi, C., & Zecca, C. (2024). Efficacy and safety of the implantable, magnetic resonance imaging‐compatible StimRouter neuromodulation system in the treatment of refractory lower urinary tract symptoms in multiple sclerosis patients. European Journal of Neurology. https://doi.org/10.1111/ene.16146

Vancouver

Sacco R, Maino P, Koetsier E, Disanto G, Renard J, Digesu A, et al. Efficacy and safety of the implantable, magnetic resonance imaging‐compatible StimRouter neuromodulation system in the treatment of refractory lower urinary tract symptoms in multiple sclerosis patients. European Journal of Neurology. 2024. doi:10.1111/ene.16146

BibTeX
@article{Sacco2024,
  author = {Sacco, Rosaria and Maino, Paolo and Koetsier, Eva and Disanto, Giulio and Renard, Julien and Digesu, Alex and Gobbi, Claudio and Zecca, Chiara},
  title = {Efficacy and safety of the implantable, magnetic resonance imaging‐compatible StimRouter neuromodulation system in the treatment of refractory lower urinary tract symptoms in multiple sclerosis patients},
  journal = {European Journal of Neurology},
  year = {2024},
  doi = {10.1111/ene.16146}
}
Start for free →