EUVIMEDScopri EUVIMED
Open access · CC BY-NC-ND 4.0

Current Clinical Practice and Outcomes of Valve‐In‐Valve TAVI ( ViV ‐ TAVI ): Results From the National Austrian TAVI Registry

Maximilian Will, Gudrun Lamm, Matthias Granner, Cecilia Veraar, Jennifer Steeb, Konstantin Schwarz, Chun Shing Kwok, Kseniya Halavina, Christian Nitsche, Philipp Bartko, Katharina Mascherbauer, Christina Tiller and 10 more

European Journal of Clinical Investigation · 2026-11 · 56 (11)

DOI: 10.1111/eci.70285 ↗

At a glance

Journal article in European Journal of Clinical Investigation, published online on 2026-11-22. Written by Maximilian Will and 21 co-authors. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Valve‐in‐valve transcatheter aortic valve implantation (ViV‐TAVI) has become an established treatment for degenerated surgical aortic bioprostheses. However, real‐world outcome data using contemporary transcatheter heart valves (THV) remain limited.

Aims

To evaluate procedural, haemodynamic and mid‐term clinical outcomes of ViV‐TAVI across contemporary THV platforms in a national real‐world cohort.

Methods

This national multicentre registry evaluated all ViV‐TAVI procedures performed between 2018 and 2024 with five CE‐marked THV platforms in seven Austrian centres (~85% of national TAVI activity). Outcomes were assessed according to VARC‐3 criteria, and survival was evaluated using Kaplan–Meier estimates.

Results

Two hundred and fifty‐eight patients (48.4% female, mean age 78.2 ± 9.3 years) were included. Treated bioprostheses were predominantly stented (88.8%), most commonly 21 mm (34.5%) and 23 mm (32.2%). Implanted devices were Evolut (46.1%), Sapien (36.4%), Allegra (13.6%), Acurate (2.3%) and Navitor (1.6%). Patients were highly symptomatic (NYHA III–IV: 84.0%). Valve fracture and coronary protection were performed in 11.2% and 5.4%, respectively. Discharge echocardiography showed significant differences across device groups in mean gradients, ranging from 12.4 ± 5.5 mmHg (Allegra) to 21.4 ± 8.3 mmHg (Acurate; p < 0.001). VARC‐3 complications occurred in 19.0% overall ( p = 0.081 between groups); 30‐day mortality was 4.7%. At 3 years, cumulative mortality was 13.5%.

Conclusions

This multicentre registry demonstrated favourable procedural and mid‐term clinical outcomes, while differences in post‐procedural haemodynamics across THV platforms should be interpreted as exploratory because of the markedly unequal group sizes.

Cite

APA

Will, M., Lamm, G., Granner, M., Veraar, C., Steeb, J., Schwarz, K., Kwok, C. S., Halavina, K., Nitsche, C., Bartko, P., Mascherbauer, K., Tiller, C., Publig, M., Alber, H., Rechberger, S., Grund, M., Schober, A., Delle‐Karth, G., Binder, R. K., …, & Mascherbauer, J. (2026). Current Clinical Practice and Outcomes of Valve‐In‐Valve TAVI ( ViV ‐ TAVI ): Results From the National Austrian TAVI Registry. European Journal of Clinical Investigation, 56(11). https://doi.org/10.1111/eci.70285

Vancouver

Will M, Lamm G, Granner M, Veraar C, Steeb J, Schwarz K, et al. Current Clinical Practice and Outcomes of Valve‐In‐Valve TAVI ( ViV ‐ TAVI ): Results From the National Austrian TAVI Registry. European Journal of Clinical Investigation. 2026;56(11). doi:10.1111/eci.70285

BibTeX
@article{Will2026,
  author = {Will, Maximilian and Lamm, Gudrun and Granner, Matthias and Veraar, Cecilia and Steeb, Jennifer and Schwarz, Konstantin and Kwok, Chun Shing and Halavina, Kseniya and Nitsche, Christian and Bartko, Philipp and Mascherbauer, Katharina and Tiller, Christina and Publig, Maximilian and Alber, Hannes and Rechberger, Stefan and Grund, Michael and Schober, Andreas and Delle‐Karth, Georg and Binder, Ronald K. and Bauer, Axel and Hengstenberg, Christian and Mascherbauer, Julia},
  title = {Current Clinical Practice and Outcomes of Valve‐In‐Valve TAVI ( ViV ‐ TAVI ): Results From the National Austrian TAVI Registry},
  journal = {European Journal of Clinical Investigation},
  year = {2026},
  volume = {56},
  number = {11},
  doi = {10.1111/eci.70285}
}
Start for free →