EUVIMEDEUVIMED entdecken
MetaanalyseSystematische ÜbersichtÜbersichtsarbeit

External stenting for saphenous vein grafts in coronary artery bypass grafting: A meta‐analysis

Huiru Chen, Zilan Wang, Ke Si, Xiaoxiao Wu, Hanyu Ni, Yanbing Tang, Wei Liu, Zhong Wang iD

European Journal of Clinical Investigation · 2023

DOI: 10.1111/eci.14046 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift European Journal of Clinical Investigation, 2023. Verfasst von Huiru Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery & Brain and Nerve Research Laboratory, The First Affiliated Hospital of Soochow University, Jiangsu Province, China. Hauptthemen laut MEDLINE: Coronary Artery Bypass, Saphenous Vein, Stents, Graft Occlusion, Vascular. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Suzhou Health Talents Training Project, Suzhou Science and Technology Development Plan Projects.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Autologous saphenous vein grafts (SVGs) are the most commonly used bypass conduits in coronary artery bypass grafting (CABG) with multivessel coronary artery disease. Although external support devices for SVGs have shown promising outcomes, the overall efficacy and safety remains controversial. We aimed to evaluate external stenting for SVGs in CABG versus non‐stented SVGs.

Methods

MEDLINE, EMBASE, Cochrane Library and clinicaltrails.gov were searched for randomized controlled trials (RCTs) to evaluate external‐stented SVGs versus non‐stented SVGs in CABG up to 31 August 2022. The risk ratio and mean difference with 95% confidence interval were analysed. The primary efficacy outcomes included intimal hyperplasia area and thickness. The secondary efficacy outcomes were graft failure (≥50% stenosis) and lumen diameter uniformity.

Results

We pooled 438 patients from three RCTs. The external stented SVGs group showed significant reductions in intimal hyperplasia area (MD: −0.78, p < 0.001, I 2 = 0%) and thickness (MD: −0.06, p < 0.001, I 2 = 0%) compared to the non‐stented SVGs group. Meanwhile, external support devices improved lumen uniformity with Fitzgibbon I classification (risk ratio (RR):1.1595, p = 0.05, I 2 = 0%). SVG failure rates were not increased in the external stented SVGs group during the short follow‐up period (RR: 1.14, p = 0.38, I 2 = 0%). Furthermore, the incidences of mortality and major cardiac and cerebrovascular events were consistent with previous reports.

Conclusions

External support devices for SVGs significantly reduced the intimal hyperplasia area and thickness, and improved the lumen uniformity, assessed with the Fitzgibbon I classification. Meanwhile, they did not increase the overall SVG failure rate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Coronary Artery BypassSaphenous VeinStentsGraft Occlusion, VascularCoronary Artery DiseaseHumansHyperplasiaRandomized Controlled Trials as Topic

Stichwörter der Autor:innen

coronary artery bypass graftingexternal support devicesmeta-analysissaphenous vein grafts

Autor:innen und Institutionen

  • Department of Neurosurgery & Brain and Nerve Research Laboratory, The First Affiliated Hospital of Soochow University, Jiangsu Province, China.
  • Department of Neurology, The First Affiliated Hospital of Soochow University, Suzhou, China.
  • Department of Cardiovascular Surgery, The First Affiliated Hospital of Soochow University, Suzhou, China.
  • Suzhou Medical College of Soochow University, Suzhou, China.
  • Department of Medicine, The Tianjin North China Hospital, Tianjin, China.

ORCID-Profile: Zhong Wang

Förderung

  • National Natural Science Foundation of China
  • Suzhou Health Talents Training Project
  • Suzhou Science and Technology Development Plan Projects

Zitieren

APA

Chen, H., Wang, Z., Si, K., Wu, X., Ni, H., Tang, Y., Liu, W., & Wang, Z. (2023). External stenting for saphenous vein grafts in coronary artery bypass grafting: A meta‐analysis. European Journal of Clinical Investigation. https://doi.org/10.1111/eci.14046

Vancouver

Chen H, Wang Z, Si K, Wu X, Ni H, Tang Y, et al. External stenting for saphenous vein grafts in coronary artery bypass grafting: A meta‐analysis. European Journal of Clinical Investigation. 2023. doi:10.1111/eci.14046

BibTeX
@article{Chen2023,
  author = {Chen, Huiru and Wang, Zilan and Si, Ke and Wu, Xiaoxiao and Ni, Hanyu and Tang, Yanbing and Liu, Wei and Wang, Zhong},
  title = {External stenting for saphenous vein grafts in coronary artery bypass grafting: A meta‐analysis},
  journal = {European Journal of Clinical Investigation},
  year = {2023},
  doi = {10.1111/eci.14046}
}
Kostenlos starten →