2D‐Echocardiographic Estimation of Right Ventricular Volumes Using a Previously Validated Geometric Model Is Associated With Outcomes After Transcatheter Tricuspid Interventions
Echocardiography · 2026-07 · 43 (7)
DOI: 10.1111/echo.70557 ↗At a glance
Journal article in Echocardiography, published online on 2026-07-11. Written by Mhd Nawar Alachkar and 9 co-authors. Institution: Department of Cardiology, Brandenburg, Medical School (MHB) Theodor Fontane, University Hospital Heart Center Brandenburg, Neuruppin, Germany. Major MEDLINE topics: Echocardiography, Heart Ventricles, Tricuspid Valve Insufficiency, Tricuspid Valve. 18 references. The full text is freely available in PubMed Central.
Abstract (original language)
Aims
To determine whether a simplified, previously proposed two‐dimensional (2D) approach to RV volume assessment can provide adjunctive prognostic information in patients undergoing Transcatheter Tricuspid Valve Interventions (TTVI). Methods and Results In this prospective single‐center study, 113 patients undergoing TTVI were included (T‐TEER; n = 91, heterotopic caval valve implantation; n = 17, and orthotopic transcatheter tricuspid valve replacement; n = 5). RV end‐diastolic and end‐systolic volumes were calculated using a previously described 2D‐based geometric model. The primary endpoint was a composite of all‐cause mortality or rehospitalization for acute decompensated heart failure at 1 year. The primary endpoint occurred in 47 patients (41.6%). In univariable Cox regression analysis, both RVEDVi (HR 1.05 per 10 mL/m 2 , 95% CI 1.01–1.10, p = 0.03) and RVESVi (HR 1.13 per 10 mL/m 2 , 95% CI 1.01–1.25, p = 0.03) were associated with adverse outcome. Receiver operating characteristic analysis identified cut‐off values of 90 mL/m 2 for RVEDVi and 35 mL/m 2 for RVESVi. Patients above these thresholds (diastolic, systolic, or both) showed significantly reduced event‐free survival (log‐rank p < 0.01). In a multivariable Cox regression analysis, RV dilatation showed a trend toward worse outcomes (HR 2.09, 95% CI 0.91–4.80, p = 0.08), whereas the TriScore remained independently associated with outcome (HR 1.30, 95% CI 1.10–1.53, p < 0.01).
Conclusion
RV volumes derived from a simple 2D echocardiographic model are associated with clinical outcomes and may provide additional information for the assessment of patients undergoing TTVI.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology, Brandenburg, Medical School (MHB) Theodor Fontane, University Hospital Heart Center Brandenburg, Neuruppin, Germany.
- Faculty of Health Sciences Brandenburg, Neuruppin, Germany.
- Clinic of Internal Medicine II, Department of Cardiology, Paracelsus Medical University, Salzburg, Austria.
- Institute of Social Medicine and Health Systems Research, Otto von Guericke University Magdeburg, Magdeburg, Germany.
Cite
APA
Alachkar, M. N., Kücken, T., Schlegl, J., Bannehr, M., Lichtenauer, M., Paar, V., Neuß, M., Haase-Fielitz, A., Edlinger, C., & Butter, C. (2026). 2D‐Echocardiographic Estimation of Right Ventricular Volumes Using a Previously Validated Geometric Model Is Associated With Outcomes After Transcatheter Tricuspid Interventions. Echocardiography, 43(7). https://doi.org/10.1111/echo.70557
Vancouver
Alachkar MN, Kücken T, Schlegl J, Bannehr M, Lichtenauer M, Paar V, et al. 2D‐Echocardiographic Estimation of Right Ventricular Volumes Using a Previously Validated Geometric Model Is Associated With Outcomes After Transcatheter Tricuspid Interventions. Echocardiography. 2026;43(7). doi:10.1111/echo.70557
BibTeX
@article{Alachkar2026,
author = {Alachkar, Mhd Nawar and Kücken, Tanja and Schlegl, Johannes and Bannehr, Marwin and Lichtenauer, Michael and Paar, Vera and Neuß, Michael and Haase-Fielitz, Anja and Edlinger, Christoph and Butter, Christian},
title = {2D‐Echocardiographic Estimation of Right Ventricular Volumes Using a Previously Validated Geometric Model Is Associated With Outcomes After Transcatheter Tricuspid Interventions},
journal = {Echocardiography},
year = {2026},
volume = {43},
number = {7},
doi = {10.1111/echo.70557}
}
EUVIMED