EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Clinical Utility and Limitations of TAPSE in Pediatric Echocardiography: A Narrative Review

Matei Mselle, Ronald Mbwasi

Echocardiography · 2026-06 · 43 (6)

DOI: 10.1111/echo.70516 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Echocardiography, online erschienen am 28.05.2026. Verfasst von Matei Mselle und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatrics, Haydom Lutheran Hospital, Haydom, Manyara, Tanzania. Hauptthemen laut MEDLINE: Echocardiography, Tricuspid Valve, Ventricular Function, Right, Heart Ventricles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Tricuspid annular plane systolic excursion (TAPSE) is widely used to assess right ventricular (RV) longitudinal systolic function in pediatric echocardiography; however, its reliability is influenced by developmental physiology.

Objective

To evaluate the clinical utility, age‐dependent variability, and limitations of TAPSE in pediatric populations.

Methods

A narrative review of literature published between 1990 and 2025 was conducted using PubMed, Scopus, and Google Scholar. Studies evaluating TAPSE in pediatric populations (0–18 years) were included.

Results

Thirty‐two studies were included. TAPSE correlates well with RV systolic function in older children and adolescents, supported by age‐ and body surface area–adjusted reference values. In neonates and infants, TAPSE is lower and more variable due to transitional physiology and altered loading conditions. TAPSE is clinically useful in pulmonary hypertension, congenital heart disease, cardiomyopathy, and posttransplant monitoring.

Conclusion

TAPSE is a practical and reproducible marker of RV systolic function in children, particularly beyond infancy. In infants, interpretation should be cautious and integrated with complementary echocardiographic indices. Composite measures such as TAPSE/PASP may improve prognostic assessment.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

EchocardiographyTricuspid ValveVentricular Function, RightHeart VentriclesVentricular Dysfunction, RightHeart Defects, CongenitalHumansReproducibility of ResultsChildInfantInfant, NewbornChild, PreschoolAdolescent

Stichwörter der Autor:innen

TAPSEcongenital heart diseaseinfantslongitudinal functionpediatric echocardiographypulmonary hypertensionright ventricular function

Autor:innen und Institutionen

  • Department of Paediatrics, Haydom Lutheran Hospital, Haydom, Manyara, Tanzania.
  • Department of Paediatric and Child Health, Kilimanjaro Christian Medical Centre, Moshi, Tanzania.
  • Kilimanjaro Christian Medical University, Moshi, Tanzania.

Zitieren

APA

Mselle, M., & Mbwasi, R. (2026). Clinical Utility and Limitations of TAPSE in Pediatric Echocardiography: A Narrative Review. Echocardiography, 43(6). https://doi.org/10.1111/echo.70516

Vancouver

Mselle M, Mbwasi R. Clinical Utility and Limitations of TAPSE in Pediatric Echocardiography: A Narrative Review. Echocardiography. 2026;43(6). doi:10.1111/echo.70516

BibTeX
@article{Mselle2026,
  author = {Mselle, Matei and Mbwasi, Ronald},
  title = {Clinical Utility and Limitations of TAPSE in Pediatric Echocardiography: A Narrative Review},
  journal = {Echocardiography},
  year = {2026},
  volume = {43},
  number = {6},
  doi = {10.1111/echo.70516}
}
Kostenlos starten →