Prognostic Value of Preoperative Left Ventricular End‐Diastolic Dimension in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation With the Venus‐A Valve
Echocardiography · 2026-06 · 43 (6)
DOI: 10.1111/echo.70509 ↗Kurz gefasst
Fachartikel in der Zeitschrift Echocardiography, online erschienen am 28.05.2026. Verfasst von Baiqiang Mei und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The First People's Hospital of Foshan, Foshan, Guangdong, China. Hauptthemen laut MEDLINE: Aortic Valve Stenosis, Transcatheter Aortic Valve Replacement, Heart Ventricles, Echocardiography. Die Arbeit nennt 38 Literaturangaben.
Abstract (Originalsprache)
Objective
Severe aortic stenosis (AS) leads to chronic pressure overload of the left ventricle (LV). We explored the prognostic value of preoperative left ventricular end‐diastolic dimension (LVEDD) dilation in patients with severe AS.
Methods
This is a retrospective study of 108 patients with severe AS who underwent transcatheter aortic valve implantation with the Venus‐A valve. These participants were assigned to the large LVEDD and non‐large LVEDD groups. The receiver operating characteristic and Kaplan–Meier curves were generated to assess the predictive value of preoperative LVEDD dilation for poor patient prognosis (readmission or death within 1 year postoperatively), as well as its effects on the readmission risk owing to heart failure, and complications and survival rates within 1 year postoperatively.
Results
Significant differences were observed between the two groups in B‐type natriuretic peptide, creatinine, aortic valve area, transfemoral access, aortic valve peak velocity, mean transvalvular pressure gradient, LVEDD, left ventricular end‐systolic dimension, left atrial dimension, interventricular septal thickness, relative wall thickness, left ventricular mass index, left ventricular ejection fraction, E/A ratio, E/e′ ratio, and stroke volume index. Preoperative LVEDD dilation showed a predictive value for poor patient prognosis (AUC = 0.843; 95%CI: 0.761–0.906, 50.9 mm cut‐off value, 99.9% sensitivity, 62.07% specificity). Preoperative LVEDD dilation was an independent influencing factor for poor prognosis within 1 year postoperatively, associated with increased readmission risk and reduced patient survival rate.
Conclusion
Preoperative LVEDD dilation is an independent influencing factor for poor postoperative prognosis in patients. It helps predict poor prognosis within 1 year postoperatively.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, The First People's Hospital of Foshan, Foshan, Guangdong, China.
- Department of Ultrasound, The First People's Hospital of Foshan, Foshan, Guangdong, China.
- Department of Anesthesiology, The First People's Hospital of Foshan, Foshan, Guangdong, China.
ORCID-Profile: Zhaoyan Xu
Zitieren
APA
Mei, B., Xu, Z., Li, J., Cen, J., Wu, X., Wang, F., Zheng, X., Mo, Z., Wu, Y., Chen, H., Li, W., & Chen, L. (2026). Prognostic Value of Preoperative Left Ventricular End‐Diastolic Dimension in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation With the Venus‐A Valve. Echocardiography, 43(6). https://doi.org/10.1111/echo.70509
Vancouver
Mei B, Xu Z, Li J, Cen J, Wu X, Wang F, et al. Prognostic Value of Preoperative Left Ventricular End‐Diastolic Dimension in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation With the Venus‐A Valve. Echocardiography. 2026;43(6). doi:10.1111/echo.70509
BibTeX
@article{Mei2026,
author = {Mei, Baiqiang and Xu, Zhaoyan and Li, Jian and Cen, Jinming and Wu, Xuefeng and Wang, Fei and Zheng, Xueqin and Mo, Zhan and Wu, Yangfan and Chen, Huomei and Li, Weijie and Chen, Lihong},
title = {Prognostic Value of Preoperative Left Ventricular End‐Diastolic Dimension in Patients With Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation With the Venus‐A Valve},
journal = {Echocardiography},
year = {2026},
volume = {43},
number = {6},
doi = {10.1111/echo.70509}
}
EUVIMED