EUVIMEDOntdek EUVIMED
Crossref

Clinical Utility of Mechanical Echocardiographic Dispersion to Assess Left Ventricular Function and Ischemia or Infarction Detected by Gated 99M‐Tc Sestamibi‐SPECT

Adrian Espejel-Guzman iD, Alfonso Gonzalez-Trejo iD, Neftali Eduardo Antonio-Villa iD, Enrique C Guerra iD, Erick Alexanderson-Rosas iD, Nilda Espinola-Zavaleta iD

Echocardiography · 2026-05 · 43 (5)

DOI: 10.1111/echo.70481 ↗

At a glance

Journal article in Echocardiography, published online on 2026-05-06. Written by Adrian Espejel-Guzman and 5 co-authors. Institution: National Medical Center Siglo XXI, Mexican Institute of Social Security, Cardiology Hospital, Mexico City, Mexico. Major MEDLINE topics: Technetium Tc 99m Sestamibi, Ventricular Dysfunction, Left, Myocardial Infarction, Echocardiography, Three-Dimensional. 25 references.

SamenvattingSubjectsBibliografische gegevensCiteRelated studies

Abstract (original language)

Background

Coronary artery disease (CAD) remains the leading cause of morbidity and mortality worldwide. Echocardiographic assessment of left ventricular (LV) asynchrony may provide additional value for detecting ischemia or infarction.

Objectives

To assess the systolic and diastolic mechanical dispersion (MD) by 3D‐echocardiography and its correlation with left ventricular ejection fraction (LVEF) and ischemia or infarction by myocardial perfusion study (MPS) gated 99m‐Tc Sestamibi‐SPECT.

Methods

Cross‐sectional study of patients with angina. Systolic and diastolic MD were defined as the standard deviation (SD) of the time to reach minimum ventricular volume, corrected for the R–R interval. Association with LVEF was assessed with correlation and linear regression. ROC curves identified ischemia or infarction and compared with E/A ratio, TRIVI, and E/e’ ratio.

Results

205 patients were studied with median age 62 (IQR: 54–69) years. 51% ( n = 104) presented ischemia or infarction. We observed a negative correlation with systolic ( r = −0.343, 95% −0.459 to −0.215; p < 0.001) and diastolic ( r = −0.184, 95% −0.314 to ‐0.047; p < 0.01) MD and MPS‐LVEF, which contributes to 8.9% and 11.8% of variance, respectively. Both parameters displayed an area under the curve (AUC) of 0.634 (95% 0.559–0.709, p < 0.001) and 0.604 (95% CI 0.527–0.679, p < 0.001) are shown to detect ischemia/infarction. In patients with transmural infarction the AUC for systolic MD improved to 0.691 (95% 0.582–0.801, p < 0.05).

Conclusions

Systolic and diastolic MD are useful and simple parameters for assessment of LV function and ischemia or infarction.

Subjects

MeSH terms (MEDLINE)

Technetium Tc 99m SestamibiVentricular Dysfunction, LeftMyocardial InfarctionEchocardiography, Three-DimensionalMyocardial IschemiaHumansFemaleMaleMiddle AgedCross-Sectional StudiesReproducibility of ResultsSensitivity and SpecificityAgedRadiopharmaceuticalsStroke Volume

Author keywords

3D echocardiographySPECTmechanical dispersionmyocardial perfusion study

Substances

Technetium Tc 99m SestamibiRadiopharmaceuticals

Authors and institutions

  • National Medical Center Siglo XXI, Mexican Institute of Social Security, Cardiology Hospital, Mexico City, Mexico.
  • Department of Nuclear Cardiology, National Institute of Cardiology Ignacio Chavez, Mexico City, Mexico.
  • Department of Endocrinology, National Institute of Cardiology Ignacio Chavez, Mexico City, Mexico.
  • Department of Echocardiography, ABC Medical Center, P.A.I., Mexico City, Mexico.

ORCID profiles: Adrian Espejel-Guzman, Alfonso Gonzalez-Trejo, Neftali Eduardo Antonio-Villa, Enrique C Guerra, Erick Alexanderson-Rosas, Nilda Espinola-Zavaleta

Cite

APA

Espejel-Guzman, A., Gonzalez-Trejo, A., Antonio-Villa, N. E., Guerra, E. C., Alexanderson-Rosas, E., & Espinola-Zavaleta, N. (2026). Clinical Utility of Mechanical Echocardiographic Dispersion to Assess Left Ventricular Function and Ischemia or Infarction Detected by Gated 99M‐Tc Sestamibi‐SPECT. Echocardiography, 43(5). https://doi.org/10.1111/echo.70481

Vancouver

Espejel-Guzman A, Gonzalez-Trejo A, Antonio-Villa NE, Guerra EC, Alexanderson-Rosas E, Espinola-Zavaleta N. Clinical Utility of Mechanical Echocardiographic Dispersion to Assess Left Ventricular Function and Ischemia or Infarction Detected by Gated 99M‐Tc Sestamibi‐SPECT. Echocardiography. 2026;43(5). doi:10.1111/echo.70481

BibTeX
@article{EspejelGuzman2026,
  author = {Espejel-Guzman, Adrian and Gonzalez-Trejo, Alfonso and Antonio-Villa, Neftali Eduardo and Guerra, Enrique C and Alexanderson-Rosas, Erick and Espinola-Zavaleta, Nilda},
  title = {Clinical Utility of Mechanical Echocardiographic Dispersion to Assess Left Ventricular Function and Ischemia or Infarction Detected by Gated 99M‐Tc Sestamibi‐SPECT},
  journal = {Echocardiography},
  year = {2026},
  volume = {43},
  number = {5},
  doi = {10.1111/echo.70481}
}
Start for free →