EUVIMEDAvasta EUVIMED
Open access · CC BY 4.0

Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic‐Androgenic Steroids

Florence Place, Chloe Hamilton, Harry Carpenter, Luca J Howard, Barbara N Morrison, Neil Chester, Robert Cooper, Ben N Stansfield, Keith P George, Peter Angell, David Oxborough

Echocardiography · 2026-04 · 43 (4)

DOI: 10.1111/echo.70454 ↗

At a glance

Journal article in Echocardiography, published online on 2026-04-10. Written by Florence Place and 10 co-authors. Institution: Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK. Major MEDLINE topics: Echocardiography, Heart Ventricles, Resistance Training, Heart Atria. Cited 1 times so far (Crossref); 52 references. The full text is freely available (open access, CC BY 4.0).

AbstraktSubjectsBibliograafilised andmedCiteRelated studies

Abstract (original language)

Purpose

The use of Anabolic‐Androgenic Steroids (AAS) is well documented in resistance trained individuals, despite reports of myocardial inflammation and fibrosis. Calibrated integrated backscatter (ciB) is an echocardiographic technique to measure ultrasonic reflectivity of the left ventricular (LV) myocardium and is a marker for tissue characterization. This study assessed ciB in both AAS using and non‐using resistance trained individuals and documented any relationship to LV and left atrial (LA) structure and function.

Methods

Male ( n = 120) and female ( n = 21) resistance trained individuals (age 30 ± 7 years); current (CU; n = 95) and non‐users (NU; n = 46) of AAS were recruited. Comprehensive echocardiography with strain imaging was performed. ciB was measured from a parasternal long axis and LA stiffness index (E/E′/LA reservoir strain) and left atrioventricular coupling index (LA end‐diastolic volume/LV end‐diastolic volume) were calculated. Results ciB was significantly higher in CU (–19.54 ± 4.63) than NU (–20.88 ± 3.94, p = 0.047). A significant positive correlation was observed between ciB and LV mass index (r s (139) = 0.318, p < 0.001), E/E′ (r(138) = 0.169, p = 0.043), LA conduit strain (r(135) = –0.174, p = 0.043), LA stiffness index (r s (134) = 0.246, p = 0.004), and left atrioventricular coupling index (r(134) = 0.241, p = 0.005). ciB was not associated with any LV systolic functional parameter (global longitudinal strain or ejection fraction).

Conclusions

Resistance trained individuals using AAS have significantly higher ciB than non‐users, suggesting differential myocardial tissue characteristics within this population. The presence of higher levels of ciB was significantly associated with LV geometry and LV diastolic function which may indicate a role of ciB in identifying early cardiac risk in this population.

Subjects

MeSH terms (MEDLINE)

EchocardiographyHeart VentriclesResistance TrainingHeart AtriaVentricular RemodelingHumansMaleFemaleAnabolic Androgenic SteroidsAdultGlobal Longitudinal StrainReproducibility of Results

Author keywords

anabolic‐androgenic steroidscalibrated integrated backscattercardiac remodelingechocardiography

Substances

Anabolic Androgenic Steroids

Authors and institutions

  • Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, UK.
  • School of Human Kinetics, Trinity Western University, Langley, British Columbia, Canada.
  • Department of Molecular Medicine, Center for Inflammation Science and Systems Medicine, UF Scripps Institute for Biomedical Innovation and Technology, Jupiter, Florida, USA.
  • School of Sports and Exercise Science, Liverpool Hope University, Liverpool, UK.

Cite

APA

Place, F., Hamilton, C., Carpenter, H., Howard, L. J., Morrison, B. N., Chester, N., Cooper, R., Stansfield, B. N., George, K. P., Angell, P., & Oxborough, D. (2026). Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic‐Androgenic Steroids. Echocardiography, 43(4). https://doi.org/10.1111/echo.70454

Vancouver

Place F, Hamilton C, Carpenter H, Howard LJ, Morrison BN, Chester N, et al. Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic‐Androgenic Steroids. Echocardiography. 2026;43(4). doi:10.1111/echo.70454

BibTeX
@article{Place2026,
  author = {Place, Florence and Hamilton, Chloe and Carpenter, Harry and Howard, Luca J and Morrison, Barbara N and Chester, Neil and Cooper, Robert and Stansfield, Ben N and George, Keith P and Angell, Peter and Oxborough, David},
  title = {Calibrated Integrated Backscatter Is Associated With Increased Left Ventricular Concentricity and Left Atrial Stiffness in Resistance Trained Individuals Using Anabolic‐Androgenic Steroids},
  journal = {Echocardiography},
  year = {2026},
  volume = {43},
  number = {4},
  doi = {10.1111/echo.70454}
}
Start for free →