Eccentricity Index Is Associated With Pulmonary Arterial Hypertension in Children After Repair of Complete Atrioventricular Septal Defects
Echocardiography · 2026-04 · 43 (4)
DOI: 10.1111/echo.70451 ↗At a glance
Journal article in Echocardiography, published online on 2026-04-08. Written by Charles T Simpkin and 5 co-authors. Institution: Department of Pediatrics, University of Colorado Medical Campus, Aurora, Colorado, USA. Major MEDLINE topics: Heart Septal Defects, Echocardiography, Pulmonary Arterial Hypertension, Hypertension, Pulmonary. 19 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NHLBI NIH HHS, Matthew's Hearts of Hope Foundation Research Grant.
Topics: Kinderkrankenpflege
Abstract (original language)
Introduction
Eccentricity Index is an echocardiographic predictor of disease severity in children with pulmonary arterial hypertension (PAH). Its utility after atrioventricular septal defect (AVSD) repair remains unclear due to surgical manipulation of the ventricular septum. We evaluated end‐systolic (EIs) and maximal (EIm) as predictors of hemodynamics post‐AVSD repair.
Methods
Cohort 1 was 89 children, 5–24 months after complete AVSD repair, and similarly aged controls. Subgroups of those with (+) and without (−) PAH were based on other echocardiographic markers of PAH. Cohort 2 was 20 children who underwent cardiac catheterization after AVSD repair. EIs and EIm were calculated as the ratio of the left ventricular diameter parallel to the septum divided by the perpendicular diameter measured at end systole and maximal post‐systolic flattening, respectively.
Results
In Cohort 1, EIs and EIm in AVSD cases were greater than in controls. Both were highest in PAH(+) patients, followed by PAH(−), followed by controls. EIs predicted echo‐estimated right ventricular systolic pressure, while EIm did not. In Cohort 2, EIs and EIm predicted RVSP ≥ 35 mmHg, while only EIs predicted PVRi ≥3 Wu*m 2 . An EIs threshold of 1.28 optimally predicted elevated RVSP (AUC 0.761) and PVRi (AUC 0.779).
Conclusions
After AVSD repair, EIs and EIm are elevated compared to those of otherwise healthy children. However, significant elevation (Eis > 1.28) may still be useful to differentiate those with and without PAH. A multiparametric approach may be needed for borderline EIs (1.09–1.28). These findings support EI as a non‐invasive screening tool to identify PAH in children after AVSD repair.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Pediatrics, University of Colorado Medical Campus, Aurora, Colorado, USA.
- Heart Institute, Children's Hospital Colorado, Aurora, Colorado, USA.
Funding
- NHLBI NIH HHS
- Matthew's Hearts of Hope Foundation Research Grant
Cite
APA
Simpkin, C. T., DeLima, M., MacBeth, M., Burkett, D. A., Ivy, D. D., & Frank, B. S. (2026). Eccentricity Index Is Associated With Pulmonary Arterial Hypertension in Children After Repair of Complete Atrioventricular Septal Defects. Echocardiography, 43(4). https://doi.org/10.1111/echo.70451
Vancouver
Simpkin CT, DeLima M, MacBeth M, Burkett DA, Ivy DD, Frank BS. Eccentricity Index Is Associated With Pulmonary Arterial Hypertension in Children After Repair of Complete Atrioventricular Septal Defects. Echocardiography. 2026;43(4). doi:10.1111/echo.70451
BibTeX
@article{Simpkin2026,
author = {Simpkin, Charles T and DeLima, Marissa and MacBeth, Morgan and Burkett, Dale A and Ivy, D Dunbar and Frank, Benjamin S},
title = {Eccentricity Index Is Associated With Pulmonary Arterial Hypertension in Children After Repair of Complete Atrioventricular Septal Defects},
journal = {Echocardiography},
year = {2026},
volume = {43},
number = {4},
doi = {10.1111/echo.70451}
}