Echocardiographic Evaluation of Global Cardiac Function in Systemic Sclerosis‐Associated Pulmonary Arterial Hypertension: An Integrated Review of Parameters and Techniques
Echocardiography · 2026-04 · 43 (4)
DOI: 10.1111/echo.70442 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Echocardiography, online erschienen am 01.04.2026. Verfasst von Zitong Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Diagnosis, Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China. Hauptthemen laut MEDLINE: Scleroderma, Systemic, Echocardiography, Hypertension, Pulmonary, Pulmonary Arterial Hypertension. Die Arbeit nennt 57 Literaturangaben. Gefördert von: Health and Medical Technology Project o1 the Health Commission of Inner Mongolia Autonomous Region, General Program of Inner Mongolia Medical University, Natural Science Foundation of Inner Mongolia Autonomous Region.
Abstract (Originalsprache)
Systemic sclerosis (SSc) is a connective tissue disease frequently complicated by pulmonary arterial hypertension (PAH), a leading cause of morbidity and mortality. Global cardiac function is a key determinant of prognosis and treatment response in SSc‐PAH, necessitating precise and dynamic assessment. Echocardiography provides a comprehensive, noninvasive modality for this purpose. This narrative review synthesizes recent advances in echocardiographic evaluation of global cardiac function in SSc‐PAH. It covers established parameters of right and left ventricular function, emerging indices such as the TAPSE/sPAP ratio and atrial strain, and the role of advanced techniques including stress echocardiography and speckle‐tracking imaging. The integration of these approaches enhances early detection, risk stratification, and therapeutic monitoring. Future directions, including three‐dimensional echocardiography and artificial intelligence, are highlighted for their potential to refine a comprehensive, ultrasound‐based assessment framework for SSc‐PAH.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound Diagnosis, Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, China.
ORCID-Profile: Xiaoshan Zhang, Shasha Duan
Förderung
- Health and Medical Technology Project o1 the Health Commission of Inner Mongolia Autonomous Region
- General Program of Inner Mongolia Medical University
- Natural Science Foundation of Inner Mongolia Autonomous Region
- Inner Mongolia Autonomous Region Science and Technology Program Project
- National Natural Science Foundation of China
- Youth Backbone Project of Affiliated Hospital of Inner Mongolia Medical University
Zitieren
APA
Zhang, Z., Shi, Y., Liu, Y., Cao, Y., Zhang, X., & Duan, S. (2026). Echocardiographic Evaluation of Global Cardiac Function in Systemic Sclerosis‐Associated Pulmonary Arterial Hypertension: An Integrated Review of Parameters and Techniques. Echocardiography, 43(4). https://doi.org/10.1111/echo.70442
Vancouver
Zhang Z, Shi Y, Liu Y, Cao Y, Zhang X, Duan S. Echocardiographic Evaluation of Global Cardiac Function in Systemic Sclerosis‐Associated Pulmonary Arterial Hypertension: An Integrated Review of Parameters and Techniques. Echocardiography. 2026;43(4). doi:10.1111/echo.70442
BibTeX
@article{Zhang2026,
author = {Zhang, Zitong and Shi, Yilu and Liu, Yang and Cao, Yiying and Zhang, Xiaoshan and Duan, Shasha},
title = {Echocardiographic Evaluation of Global Cardiac Function in Systemic Sclerosis‐Associated Pulmonary Arterial Hypertension: An Integrated Review of Parameters and Techniques},
journal = {Echocardiography},
year = {2026},
volume = {43},
number = {4},
doi = {10.1111/echo.70442}
}
EUVIMED