EUVIMEDОткрийте EUVIMED
Crossref

Accuracy of Echocardiographic Parameters in Diagnosing Pulmonary Hypertension in Adult Patients With Uncorrected Secundum Atrial Septal Defect

Yohanes Adeo Caesar Evan Santoso, Real Kusumanjaya Marsam, Dyah Wulan Anggrahini, Anggoro Budi Hartopo, Lucia Kris Dinarti

Echocardiography · 2026-04 · 43 (4)

DOI: 10.1111/echo.70427 ↗

At a glance

Journal article in Echocardiography, published online on 2026-03-31. Written by Yohanes Adeo Caesar Evan Santoso and 4 co-authors. Institution: Department of Cardiology and Vascular Medicine, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia. Major MEDLINE topics: Hypertension, Pulmonary, Heart Septal Defects, Atrial, Echocardiography. 27 references.

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

Purpose

Pulmonary hypertension (PH) is a progressive complication in adults with atrial septal defect (ASD), significantly impacting prognosis. Although right heart catheterization (RHC) is the gold standard for diagnosis, it is invasive. This study aimed to evaluate the diagnostic accuracy of various echocardiographic parameters compared to RHC for detecting PH specifically in adult patients with uncorrected secundum ASD.

Methods

This cross‐sectional diagnostic study utilized retrospective data from the COngenital HeARt Disease in adult and Pulmonary Hypertension (COHARD‐PH) registry at Sardjito Hospital, Indonesia. The subjects were adult patients with uncorrected secundum ASD who underwent both echocardiography and RHC between January 2023 and July 2025. PH was established based on RHC, defined as mean pulmonary artery pressure (mPAP) > 20 mm Hg. ROC curve analysis and 2 × 2 tables were used to determine the cutoff values, sensitivity, specificity, and accuracy of echocardiographic parameters using RHC as the gold standard.

Results

The study included 97 subjects, with 87 subjects (89.7%) suffering from PH. The echocardiographic parameters with the best accuracy for diagnosing PH were PVR estimation (84.54%), TRV (81.45%), TRPG (81.44%), as well as PASP, mPAP, and the TAPSE/PASP ratio (80.41%). The optimal TRV cutoff value for detecting PH was ≥2.96 m/s (sensitivity 81.6%, specificity 80%).

Conclusion

Pressure and resistance based echocardiographic parameters, namely, TRV, TRPG, PASP, mPAP, the TAPSE/PASP ratio, and PVR estimation, demonstrate good accuracy in diagnosing PH in adult patients with uncorrected secundum ASD. A TRV cutoff of ≥2.96 m/s improves specificity in this population.

Subjects

MeSH terms (MEDLINE)

Hypertension, PulmonaryHeart Septal Defects, AtrialEchocardiographyHumansFemaleRetrospective StudiesMaleSensitivity and SpecificityCross-Sectional StudiesAdultReproducibility of ResultsCardiac CatheterizationMiddle Aged

Author keywords

atrial septal defectdiagnostic accuracyechocardiographypulmonary hypertensionright heart catheterization

Authors and institutions

  • Department of Cardiology and Vascular Medicine, Faculty of Medicine, Public Health and Nursing, Universitas Gadjah Mada, Yogyakarta, Indonesia.

Cite

APA

Santoso, Y. A. C. E., Marsam, R. K., Anggrahini, D. W., Hartopo, A. B., & Dinarti, L. K. (2026). Accuracy of Echocardiographic Parameters in Diagnosing Pulmonary Hypertension in Adult Patients With Uncorrected Secundum Atrial Septal Defect. Echocardiography, 43(4). https://doi.org/10.1111/echo.70427

Vancouver

Santoso YACE, Marsam RK, Anggrahini DW, Hartopo AB, Dinarti LK. Accuracy of Echocardiographic Parameters in Diagnosing Pulmonary Hypertension in Adult Patients With Uncorrected Secundum Atrial Septal Defect. Echocardiography. 2026;43(4). doi:10.1111/echo.70427

BibTeX
@article{Santoso2026,
  author = {Santoso, Yohanes Adeo Caesar Evan and Marsam, Real Kusumanjaya and Anggrahini, Dyah Wulan and Hartopo, Anggoro Budi and Dinarti, Lucia Kris},
  title = {Accuracy of Echocardiographic Parameters in Diagnosing Pulmonary Hypertension in Adult Patients With Uncorrected Secundum Atrial Septal Defect},
  journal = {Echocardiography},
  year = {2026},
  volume = {43},
  number = {4},
  doi = {10.1111/echo.70427}
}
Start for free →