EUVIMEDEUVIMED entdecken
Crossref

Influence of Venous Access Site and Right Atrial Anatomical Variants on the Detection of Patent Foramen Ovale During Agitated Saline Contrast Transesophageal Echocardiography

Damla Raimoglou iD, Deniz Mutlu, Bilgehan Karadag, Baris Ikitimur, Arda Çeviker, Ayten Ozal, Efekan Dogramaci, A Atıl Aygun, Utku Raimoglu, Kardelen Ohtaroglu Tokdil, Hasan Tokdil, Eser Durmaz

Echocardiography · 2026

DOI: 10.1111/echo.70401 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Echocardiography, 2026. Verfasst von Damla Raimoglou und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey. Hauptthemen laut MEDLINE: Echocardiography, Transesophageal, Foramen Ovale, Patent, Contrast Media, Saline Solution. Die Arbeit nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Contrast‐enhanced transesophageal echocardiography (cTEE) is the gold standard for the detection of patent foramen ovale (PFO). However, the diagnostic yield may vary depending on the venous injection site of the saline contrast medium and the presence of anatomical variants such as the Eustachian valve (EV) or Chiari network (CN), which can alter right atrial flow dynamics. This study aims to evaluate whether the route of injection—an upper‐extremity vein vs. a lower‐extremity vein—affects PFO detection and whether the presence of EV or CN further influences shunt visualization.

Methods

We prospectively enrolled 174 patients referred for cTEE for suspected cardioembolic etiology. Agitated saline contrast was injected via an upper‐extremity vein (brachial/antecubital vein; UEV) and via a lower‐extremity vein (saphenous veins; LEV) during standardized Valsalva maneuver. Each route was tested with up to three adequately performed injections irrespective of the alternate‐route result. PFO was defined as microbubbles visualized traversing the interatrial septum within the first five cardiac cycles after right atrial opacification and Valsalva release. EV/CN was recorded. EV length and mobility and atrial septal aneurysm (ASA) were assessed by re‐review of archived TEE images.

Results

PFO was detected in 73/174 (42.0%) by either route. UEV was positive in 58/174 (33.3%) and LEV in 64/174 (36.8%) ( p = 0.307). Among PFO‐positive patients, 49 (67.1%) were positive with both routes, 9 (12.3%) only with UEV injection, and 15 (20.5%) only with LEV injection. EV was present in 56/174 (32.2%) and CN in 4/174 (2.3%); among PFO‐positive patients, EV was present in 31/73 (42.5%) and CN in 2/73 (2.7%). In EV‐positive PFO patients (n = 31), positive LEV injection detected 31/31 (100%) whereas positive UEV injection detected 17/31 (54.8%) ( p = 0.000122). LEV‐only positivity occurred in 9/11 patients with EV length ≥10 mm versus 5/20 with EV length

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Echocardiography, TransesophagealForamen Ovale, PatentContrast MediaSaline SolutionHeart AtriaHumansFemaleMaleReproducibility of ResultsMiddle AgedSensitivity and SpecificityProspective StudiesInjections, IntravenousImage Enhancement

Stichwörter der Autor:innen

Contrast transesophageal echocardiography (cTEE)Eustachian valve (EV)Patent foramen ovale (PFO)

Substanzen

Contrast MediaSaline Solution

Autor:innen und Institutionen

  • Department of Cardiology, Cerrahpasa Medical School, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Department of Cardiology, SUNY Downstate Medical Center, Brooklyn, USA.
  • Department of Cardiology, Yedikule Surp Pırgic Armenian Hospital, Istanbul, Turkey.
  • Department of Cardiology, Koc University, Istanbul, Turkey.

ORCID-Profile: Damla Raimoglou

Zitieren

APA

Raimoglou, D., Mutlu, D., Karadag, B., Ikitimur, B., Çeviker, A., Ozal, A., Dogramaci, E., Aygun, A. A., Raimoglu, U., Tokdil, K. O., Tokdil, H., & Durmaz, E. (2026). Influence of Venous Access Site and Right Atrial Anatomical Variants on the Detection of Patent Foramen Ovale During Agitated Saline Contrast Transesophageal Echocardiography. Echocardiography. https://doi.org/10.1111/echo.70401

Vancouver

Raimoglou D, Mutlu D, Karadag B, Ikitimur B, Çeviker A, Ozal A, et al. Influence of Venous Access Site and Right Atrial Anatomical Variants on the Detection of Patent Foramen Ovale During Agitated Saline Contrast Transesophageal Echocardiography. Echocardiography. 2026. doi:10.1111/echo.70401

BibTeX
@article{Raimoglou2026,
  author = {Raimoglou, Damla and Mutlu, Deniz and Karadag, Bilgehan and Ikitimur, Baris and Çeviker, Arda and Ozal, Ayten and Dogramaci, Efekan and Aygun, A Atıl and Raimoglu, Utku and Tokdil, Kardelen Ohtaroglu and Tokdil, Hasan and Durmaz, Eser},
  title = {Influence of Venous Access Site and Right Atrial Anatomical Variants on the Detection of Patent Foramen Ovale During Agitated Saline Contrast Transesophageal Echocardiography},
  journal = {Echocardiography},
  year = {2026},
  doi = {10.1111/echo.70401}
}
Kostenlos starten →