EUVIMEDOdkrijte EUVIMED
Crossref

Percutaneous Coronary Sinus Catheter Placement and Management With Transesophageal Echocardiography for Robotic Mitral Valve Surgery

Katherine W Sun iD, Donald Glower, Angela Pollak, Madison Goldberger, Alina Nicoara iD

Echocardiography · 2025

DOI: 10.1111/echo.70327 ↗

At a glance

Journal article in Echocardiography, 2025. Written by Katherine W Sun and 4 co-authors. Institution: Division of Cardiothoracic Anesthesia, Department of Anesthesia, Duke University Medical Center, Durham, North Carolina, USA. Major MEDLINE topics: Echocardiography, Transesophageal, Robotic Surgical Procedures, Coronary Sinus, Mitral Valve. 19 references.

PovzetekSubjectsBibliografski podatkiCiteRelated studies

Abstract (original language)

Introduction

Placement of a percutaneous coronary sinus catheter (CSC) for retrograde cardioplegia delivery in minimally invasive cardiac surgery has been implemented at various centers. While several techniques have been described for catheter placement, we present our experience utilizing transesophageal echocardiography (TEE) alone for guiding the successful placement and management of percutaneous CSC during robotic mitral valve repair (MVr).

Methods

We retrospectively studied all adult patients who underwent planned robotic MVr by a single surgeon at our institution from August 2013 to December 2021. Confirmation of successful CSC placement was made by review of electronic medical records and TEE data.

Results

Out of 144 patients in the study cohort, 135 (94%) patients had successful CSC placement. The median time from anesthesia start in the operating room to surgical incision was 93 min (interquartile range 82–103 min). Of the 135 patients with successful CSC placement, 122 patients (90%) had maintenance of cardiac arrest during cardiopulmonary bypass with retrograde cardioplegia only. Two patients (1.4%) had complications; one had an injury of the coronary sinus (unrelated to CSC placement) requiring sternotomy, and one had an episode of ventricular tachycardia requiring defibrillation.

Discussion

In our experience, TEE guidance offers an effective approach for percutaneous CSC placement without requiring fluoroscopic guidance. It allows the safe conduct of surgery with multidose administration of retrograde cardioplegia. The alternative to placing a percutaneous CSC is administration of antegrade cardioplegia only, which may not be feasible in all patients, and if feasible, may have limitations in robotic MVr.

Subjects

MeSH terms (MEDLINE)

Echocardiography, TransesophagealRobotic Surgical ProceduresCoronary SinusMitral ValveCardiac CatheterizationHumansMaleFemaleRetrospective StudiesMiddle AgedAgedHeart Arrest, Induced

Author keywords

coronary sinusminimally invasivemitral valve repairretrograde cardioplegiaestransesophageal echocardiography

Authors and institutions

  • Division of Cardiothoracic Anesthesia, Department of Anesthesia, Duke University Medical Center, Durham, North Carolina, USA.
  • Division of Cardiothoracic Surgery, Department of Surgery, Duke University Medical Center, Durham, North Carolina, USA.
  • Department of Anesthesiology and Pain Medicine, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.

ORCID profiles: Katherine W Sun, Alina Nicoara

Cite

APA

Sun, K. W., Glower, D., Pollak, A., Goldberger, M., & Nicoara, A. (2025). Percutaneous Coronary Sinus Catheter Placement and Management With Transesophageal Echocardiography for Robotic Mitral Valve Surgery. Echocardiography. https://doi.org/10.1111/echo.70327

Vancouver

Sun KW, Glower D, Pollak A, Goldberger M, Nicoara A. Percutaneous Coronary Sinus Catheter Placement and Management With Transesophageal Echocardiography for Robotic Mitral Valve Surgery. Echocardiography. 2025. doi:10.1111/echo.70327

BibTeX
@article{Sun2025,
  author = {Sun, Katherine W and Glower, Donald and Pollak, Angela and Goldberger, Madison and Nicoara, Alina},
  title = {Percutaneous Coronary Sinus Catheter Placement and Management With Transesophageal Echocardiography for Robotic Mitral Valve Surgery},
  journal = {Echocardiography},
  year = {2025},
  doi = {10.1111/echo.70327}
}
Start for free →