EUVIMEDScopri EUVIMED
Systematische ÜbersichtMetaanalyse

Systematic Review of Ultrasound Diagnostic Accuracy for Senile Calcified Valvular Heart Disease

Yuanhong Huang, Jinfeng Wan, Yuling Duan, Xun Guo, Min Huang iD

Echocardiography · 2025

DOI: 10.1111/echo.70236 ↗

At a glance

Systematische Übersicht in Echocardiography, 2025. Written by Yuanhong Huang and 4 co-authors. Institution: Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, P.R. China. Major MEDLINE topics: Calcinosis, Heart Valve Diseases, Echocardiography. Cited 1 times so far (Crossref); 41 references.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Objective

To systematically assess the diagnostic accuracy of ultrasound for the detection and evaluation of senile calcified valvular heart disease (SCVD).

Methods

Databases including Web of Science, PubMed, Cochrane Library, Embase, Chinese Biomedical Literature Database (CBM), China National Knowledge Infrastructure (CNKI), and Wanfang and China Science and Technology Journal Database (CQVIP) were systematically queried for studies pertaining to ultrasound in the diagnosis of SCVD from inception to March 2024. Two independent reviewers conducted literature screening, data extraction, and assessment of bias risk for the included studies. Following eligibility screening, a total of 12 papers were included for data extraction and descriptive analysis. Subsequently, meta‐analysis was performed using Stata 16.0 software.

Results

A total of 12 studies were finally included. The pooled sensitivity of ultrasound was 0.95 (95% CI = 0.93–0.97), specificity was 0.96 (95% CI = 0.93–0.97), positive likelihood ratio (PLR) was 21.89 (95% CI = 13.27–36.13), negative likelihood ratio (NLR) was 0.05 (95% CI = 0.03–0.07) and diagnostic odds ratio (DOR) and area under the summary receiver operating characteristic curve (AUC) were 453.19 (95% CI = 236.57–868.16) and 0.99 (95% CI: 0.97–0.99), respectively. Sensitivity analysis was carried out after each study was excluded one by one, and the results showed that pooled sensitivity and specificity had no significant change, indicating that the stability of the meta‐analysis results was excellent.

Conclusions

Our findings suggest that ultrasound demonstrates high accuracy in diagnosing SCVD, although it does not completely eliminate the possibility of misdiagnosis or missed diagnosis. This study systematically assesses the precision of ultrasound in diagnosing SCVD, offering valuable insights for clinical application.

Subjects

MeSH terms (MEDLINE)

CalcinosisHeart Valve DiseasesEchocardiographyHumansSensitivity and SpecificityReproducibility of ResultsUltrasonographyAged

Author keywords

accuracydiagnosismeta‐analysissenile calcified valvular heart disease (SCVD)ultrasound

Authors and institutions

  • Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, Sichuan, P.R. China.
  • Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, P.R. China.
  • Department of Physiology, School of Basic Medical Sciences, Chengdu Medical College, Chengdu, Sichuan, P.R. China.

ORCID profiles: Min Huang

Cite

APA

Huang, Y., Wan, J., Duan, Y., Guo, X., & Huang, M. (2025). Systematic Review of Ultrasound Diagnostic Accuracy for Senile Calcified Valvular Heart Disease. Echocardiography. https://doi.org/10.1111/echo.70236

Vancouver

Huang Y, Wan J, Duan Y, Guo X, Huang M. Systematic Review of Ultrasound Diagnostic Accuracy for Senile Calcified Valvular Heart Disease. Echocardiography. 2025. doi:10.1111/echo.70236

BibTeX
@article{Huang2025,
  author = {Huang, Yuanhong and Wan, Jinfeng and Duan, Yuling and Guo, Xun and Huang, Min},
  title = {Systematic Review of Ultrasound Diagnostic Accuracy for Senile Calcified Valvular Heart Disease},
  journal = {Echocardiography},
  year = {2025},
  doi = {10.1111/echo.70236}
}
Start for free →