EUVIMEDOpdag EUVIMED
Systematische ÜbersichtMetaanalyseOpen access · CC BY-NC-ND 4.0

Echocardiographic Parameters of Right Ventricular Size and Function Associated With Right Heart Failure After Durable Left Ventricular Assist Device Implantation—A Systematic Review and Meta‐Analysis

Echokardiografische Parameter von Größe und Funktion des rechten Ventrikels im Zusammenhang mit Rechtsherzversagen nach Implantation eines dauerhaften linksventrikulären Unterstützungssystems – systematische Übersichtsarbeit und Metaanalyse

Jia Cheng Kevyn Chai iD, Jia Le Chew, Anjalee Amarasekera, Hatem Soliman Aboumarie iD, Timothy C Tan

Echocardiography · 2025-03 · 42 (3)

DOI: 10.1111/echo.70119 ↗

Auf einen Blick

Bei Erwachsenen mit D-LVAD zeigte die transthorakale Echokardiographie eine dilatierte RV-Größe und reduzierte systolische Funktion. TAPSE und RVEDD waren mit der Entwicklung eines Rechtsherzversagens assoziiert.

Fragestellung

Welche transthorakalen Echokardiographie-Parameter von RV-Größe und -Funktion sind bei Erwachsenen mit D-LVAD mit spät einsetzendem Rechtsherzversagen nach Implantation verbunden?

Methode

Systematische Literaturrecherche zu Studien bei Erwachsenen mit D-LVAD; Suchzeitraum Januar 2003 bis August 2023, nur englischsprachige Studien. Meta-Analyse der relevanten TTE-Parameter.

Ergebnisse

350 Studien identifiziert. Neun Studien mit gepoolt 627 Patient:innen und drei Studien mit gepoolt 175 Patient:innen (40 Fälle, 135 Kontrollen) wurden metaanalysiert. RVEDD war erhöht; TAPSE, RVFAC und RVEF waren vermindert. TAPSE positiv, RVEDD negativ mit der Nicht-RVF-Gruppe assoziiert.

Einschränkungen

Further studies should also be conducted to establish post-implantation TTE reference values.

Schlussfolgerung der Autor:innen

Nach verfügbaren Studien bestanden bei D-LVAD-Patient:innen eine RV-Dilatation und eine reduzierte systolische Funktion. TAPSE und RVEDD könnten prognostische Marker für die Entwicklung eines RVF nach Implantation sein.

Kernaussagen

  • Bei D-LVAD-Patient:innen war die RV-Größe vergrößert.
  • TAPSE und RVEDD waren mit RVF nach Implantation assoziiert.
  • Post-Implantations-Referenzwerte für TTE fehlen noch.

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

At a glance

Systematische Übersicht in Echocardiography, published online on 2025-03-04. Written by Jia Cheng Kevyn Chai and 4 co-authors. Institution: Department of Cardiology, Blacktown Hospital, Western Sydney Local Health District, Blacktown, New South Wales, Australia. Major MEDLINE topics: Echocardiography, Heart Failure, Heart Ventricles, Heart-Assist Devices. Cited 8 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

Auf einen BlickAbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Late‐onset Right Ventricular (RV) failure is an established complication of Durable Left‐Ventricular Assist Device (D‐LVAD) implantation. Transthoracic echocardiography (TTE) remains the primary imaging modality for serial monitoring in this population, but its interpretation remains challenging due to device‐related changes in RV size and function and a lack of guidelines addressing this impact. This study aims to examine the diagnostic and prognostic utility of TTE parameters of RV size and function in the detection of late‐onset RV failure post‐implantation. Methods and Results A systematic literature search of medical databases was performed to identify all relevant studies assessing TTE parameters in adult patients with D‐LVADs (January 2003–August 2023; English only). Of the 350 studies identified, nine studies with a pooled cohort of 627 patients and three studies with a pooled cohort of 175 patients (40 Cases and 135 controls) were meta‐analyzed across a range of structural and functional TTE parameters. Compared to World Alliance Societies of Echocardiography (WASE) reference values, this population had dilated RV size (as quantified by RVEDD) and reduced systolic function (as quantified by TAPSE, RVFAC, and RVEF). TAPSE was positively associated with the non‐RVF group, while RVEDD was negatively associated with the non‐RVF group.

Conclusions

Based on the available studies, there was baseline RV dilatation and reduced systolic function in patients with D‐LVADs. Additionally, TAPSE and RVEDD demonstrated a statistically significant association with the development of RVF post‐implantation, indicating a potential role as prognostic markers. Further studies should also be conducted to establish post‐implantation TTE reference values.

Subjects

MeSH terms (MEDLINE)

EchocardiographyHeart FailureHeart VentriclesHeart-Assist DevicesVentricular Dysfunction, RightVentricular Function, RightHumansPrognosis

Author keywords

RVS’fractional area changeheart failurenon‐invasive cardiac Imagingright ventricular sizetransthoracic echocardiography

Authors and institutions

  • Department of Cardiology, Blacktown Hospital, Western Sydney Local Health District, Blacktown, New South Wales, Australia.
  • School of Medicine, Western Sydney University, South Penrith, Australia.
  • Westmead Heart Rhythm Institute, Faculty of Medicine and Health, University of Sydney, Sydney, Australia.
  • Department of Cardiology, Westmead Hospital, Western Sydney Local Health District, Westmead, New South Wales, Australia.
  • Department of Anaesthetics, Critical Care and Mechanical Circulatory Support, Harefield Hospital, Royal Brompton and Harefield Hospitals, London, UK.
  • School of Cardiovascular and Metabolic Medicine and Sciences, King's College London, London, UK.

ORCID profiles: Jia Cheng Kevyn Chai, Hatem Soliman Aboumarie

Cite

APA

Chai, J. C. K., Chew, J. L., Amarasekera, A., Soliman Aboumarie, H., & Tan, T. C. (2025). Echocardiographic Parameters of Right Ventricular Size and Function Associated With Right Heart Failure After Durable Left Ventricular Assist Device Implantation—A Systematic Review and Meta‐Analysis. Echocardiography, 42(3). https://doi.org/10.1111/echo.70119

Vancouver

Chai JCK, Chew JL, Amarasekera A, Soliman Aboumarie H, Tan TC. Echocardiographic Parameters of Right Ventricular Size and Function Associated With Right Heart Failure After Durable Left Ventricular Assist Device Implantation—A Systematic Review and Meta‐Analysis. Echocardiography. 2025;42(3). doi:10.1111/echo.70119

BibTeX
@article{Chai2025,
  author = {Chai, Jia Cheng Kevyn and Chew, Jia Le and Amarasekera, Anjalee and Soliman Aboumarie, Hatem and Tan, Timothy C},
  title = {Echocardiographic Parameters of Right Ventricular Size and Function Associated With Right Heart Failure After Durable Left Ventricular Assist Device Implantation—A Systematic Review and Meta‐Analysis},
  journal = {Echocardiography},
  year = {2025},
  volume = {42},
  number = {3},
  doi = {10.1111/echo.70119}
}
Start for free →