EUVIMEDОткрийте EUVIMED
Open access · CC BY-NC 4.0

Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor‐Neutral Echocardiography Software in Healthy Subjects

Aro Daniela Arockiam iD, Tiffany Dong, Ankit Agrawal, Joseph El Dahdah, Elio Haroun, Muhammad Majid, Sharmeen Sorathia, Richard A Grimm, Patrick Collier, Leonardo Rodriguez, Zoran B Popovic iD, Brian P Griffin and 1 more

Echocardiography · 2025

DOI: 10.1111/echo.70102 ↗

At a glance

Journal article in Echocardiography, 2025. Written by Aro Daniela Arockiam and 12 co-authors. Institution: Section of Cardiovascular Imaging, Department of Cardiovascular Medicine, Sydell and Arnold Miller Heart, Vascular, and Thoracic Institute, Cleveland…. Major MEDLINE topics: Echocardiography, Heart Ventricles, Ventricular Function, Left, Software. Cited 3 times so far (Crossref); 14 references. The full text is freely available (open access, CC BY-NC 4.0).

РезюмеSubjectsБиблиографски данниCiteRelated studies

Abstract (original language)

Background

Left ventricular global longitudinal strain (LVGLS) by speckle‐tracking transthoracic echocardiography (TTE) is an established measure of left ventricular systolic function with many clinical applications. Strain software has evolved to achieve vendor‐neutrality in recent developments, although there is a notable absence of external validation studies. We assessed the normal ranges and associated factors of two‐dimensional LVGLS quantification by TomTec, EchoPAC, VVI, and Epsilon contemporary strain software in a healthy cross‐sectional cohort.

Methods

One hundred healthy subjects undergoing TTE during January–April 2023 at our institution were cross‐sectionally recruited, 20 per age‐group, 50% were female, and 50% had GE and 50% Philips scans. TomTec version 51.02 (Autostrain LV), EchoPAC version 206 (AFI‐LV), VVI version (V.2.00‐070730), and Epsilon (5.0.2.11295) were utilized to quantify two‐dimensional LVGLS in all patients for comparative and regression analyses.

Results

Means and lower limits of normal (95% confidence intervals) of LVGLS were −17.1% (−17.5%, −16.7%) and −14.7% (−15.4%, −14.0%) for TomTec; −17.8% (−18.4%, −17.2%) and −14.4% (−15.3%, −13.5%) for EchoPAC; −16.3% (−16.9%, −15.7%) and −13.0% (−13.9%, −12.1%) for VVI; and −17.0% (−17.6%, −16.4%) and −12.8% (−13.8%, −11.8%) for Epsilon. Factors significantly associated with LVGLS measurements in multivariable regression analyses with their beta‐coefficients (95% CI) were female −1.36 (−2.12, −0.59), heart rate (per 10 bpm) with a coefficient of 0.38 (0.10–0.66), left ventricular ejection fraction (per 10%) −1.03 (−1.72, −0.34), and EchoPAC (vs. TomTec) −0.62 (−1.2, 0.0), VVI (vs. TomTec) 0.82 (0.23, 1.41) and Epsilon (vs. TomTec) 0.13 (−0.45, 0.72).

Conclusion

LVGLS measurements were feasible across all four strain software on both GE and Philips scans in this study. Reference ranges to define normal, abnormal, and borderline LVGLS values along with associated factors in healthy patients are reported to enable clinical applications.

Subjects

MeSH terms (MEDLINE)

EchocardiographyHeart VentriclesVentricular Function, LeftSoftwareHumansFemaleMaleReference ValuesCross-Sectional StudiesMiddle AgedAdultHealthy VolunteersReproducibility of ResultsGlobal Longitudinal Strain

Author keywords

echocardiographyleft ventriclespeckle‐trackingstrainsystolic function

Authors and institutions

  • Section of Cardiovascular Imaging, Department of Cardiovascular Medicine, Sydell and Arnold Miller Heart, Vascular, and Thoracic Institute, Cleveland, Ohio, USA.

ORCID profiles: Aro Daniela Arockiam, Zoran B Popovic, Tom Kai Ming Wang

Cite

APA

Arockiam, A. D., Dong, T., Agrawal, A., Dahdah, J. E., Haroun, E., Majid, M., Sorathia, S., Grimm, R. A., Collier, P., Rodriguez, L., Popovic, Z. B., Griffin, B. P., & Wang, T. K. M. (2025). Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor‐Neutral Echocardiography Software in Healthy Subjects. Echocardiography. https://doi.org/10.1111/echo.70102

Vancouver

Arockiam AD, Dong T, Agrawal A, Dahdah JE, Haroun E, Majid M, et al. Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor‐Neutral Echocardiography Software in Healthy Subjects. Echocardiography. 2025. doi:10.1111/echo.70102

BibTeX
@article{Arockiam2025,
  author = {Arockiam, Aro Daniela and Dong, Tiffany and Agrawal, Ankit and Dahdah, Joseph El and Haroun, Elio and Majid, Muhammad and Sorathia, Sharmeen and Grimm, Richard A and Collier, Patrick and Rodriguez, Leonardo and Popovic, Zoran B and Griffin, Brian P and Wang, Tom Kai Ming},
  title = {Reference Ranges of Left Ventricular Global Longitudinal Strain by Contemporary Vendor‐Neutral Echocardiography Software in Healthy Subjects},
  journal = {Echocardiography},
  year = {2025},
  doi = {10.1111/echo.70102}
}
Start for free →