Early Detection of Left Ventricular Dysfunction With Machine Learning‐Based Strain Imaging in Aortic Stenosis Patients
Echocardiography · 2024
DOI: 10.1111/echo.70007 ↗At a glance
Journal article in Echocardiography, 2024. Written by Amir Yahav and 1 co-authors. Institution: Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel. Major MEDLINE topics: Aortic Valve Stenosis, Ventricular Dysfunction, Left, Machine Learning, Early Diagnosis. Cited 3 times so far (Crossref); 65 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: KAMIN program of the Israel Innovation Authority.
Abstract (original language)
Purpose
Aortic stenosis (AS) is a common cardiovascular condition where early detection of left ventricular (LV) dysfunction is essential for timely intervention and optimal management. Current echocardiographic measurements, such as ejection fraction (EF), are insensitive to minor changes in LV function, and strain imaging is typically limited to the global longitudinal strain (GLS) parameter due to robustness issues. This study introduces a novel, fully automatic algorithm to enhance the detection of LV dysfunction in AS patients using multiple strain imaging parameters.
Methods
We applied supervised machine‐learning techniques to classify data from 82 severe AS patients, 96 chest pain subjects, and 319 healthy volunteers.
Results
Our model significantly outperformed EF and GLS in distinguishing AS patients from healthy volunteers (area under the curve [AUC] = 0.97 vs. 0.88 and 0.82, respectively). It also surpassed EF and GLS in differentiating AS patients from chest pain subjects (AUC = 0.95 vs. 0.90 and 0.55, respectively).
Conclusion
This novel, clinically interpretable model leverages the potential of strain imaging to enhance diagnostic accuracy and guide clinical decision‐making in LV dysfunction, thereby improving clinical practice.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Faculty of Biomedical Engineering, Technion - Israel Institute of Technology, Haifa, Israel.
ORCID profiles: Amir Yahav
Funding
- KAMIN program of the Israel Innovation Authority
Cite
APA
Yahav, A., & Adam, D. (2024). Early Detection of Left Ventricular Dysfunction With Machine Learning‐Based Strain Imaging in Aortic Stenosis Patients. Echocardiography. https://doi.org/10.1111/echo.70007
Vancouver
Yahav A, Adam D. Early Detection of Left Ventricular Dysfunction With Machine Learning‐Based Strain Imaging in Aortic Stenosis Patients. Echocardiography. 2024. doi:10.1111/echo.70007
BibTeX
@article{Yahav2024,
author = {Yahav, Amir and Adam, Dan},
title = {Early Detection of Left Ventricular Dysfunction With Machine Learning‐Based Strain Imaging in Aortic Stenosis Patients},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.70007}
}
EUVIMED