EUVIMEDEUVIMED entdecken
Studienprotokoll

Feasibility of a Cardiac Magnetic Resonance Protocol for “off‐on” Cardiac Resynchronization Therapy Evaluation

Christian Basile iD, Alessandra Scatteia, Daniele Giacopelli, Paolo Gallo, Salvatore Pezzullo, Costantino Mancusi iD, Carmine E Pascale, Paola Gargiulo, Federica Marzano, Pasquale Perrone-Filardi, Stefania Paolillo, Santo Dellegrottaglie

Echocardiography · 2024

DOI: 10.1111/echo.70003 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Echocardiography, 2024. Verfasst von Christian Basile und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Biomedical Sciences, Federico II University of Naples, Naples, Italy. Hauptthemen laut MEDLINE: Cardiac Resynchronization Therapy, Feasibility Studies, Magnetic Resonance Imaging, Cine, Heart Failure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiac resynchronization therapy (CRT) is a standard treatment for patients with heart failure and electrical dyssynchrony. Cardiac magnetic resonance (CMR) is the gold standard for assessing left ventricular (LV) function. However, the feasibility of using CMR with active CRT is still uncertain.

Purpose

To assess the feasibility of a CRT “off‐on” protocol during CMR and measure the acute effects of CRT interruption on LV function.

Methods

Patients underwent CMR before (pre‐CRT) and 6 months after (post‐CRT) an MR‐conditional CRT defibrillator implantation. The post‐CRT scan included two complete sets of cine images, one with inactive (post‐CRT OFF ) and one with active CRT (post‐CRT ON ), maintaining a continuous connection between device and programmer.

Results

Out of 29 enrolled patients, 8 (28%) had complete and analyzable post‐CRT data. Unsuccessful procedures were attributed to connection problems between the CRT device and the programmer ( n = 10), poor image quality ( n = 7), and lack of patient cooperation ( n = 4). LV ejection fraction significantly increased between pre‐CRT scan (28.1%) and both post‐CRT OFF (37.9%; p = 0.046) and post‐CRT ON CMR (35.0%; p = 0.037), with a nonstatistically significant trend toward decreased LV volumes. No adverse events or significant changes in device electrical parameters (including battery level) were detected during the post‐CMR scan period.

Conclusion

A CRT “off‐on” protocol during CMR studies can be safely executed in patients with an MR‐conditional CRT defibrillator. However, technical improvements are needed to facilitate high‐quality scans during active CRT. Favorable changes in LV function induced by CRT remodeling were not acutely reversed with the interruption of electrical therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiac Resynchronization TherapyFeasibility StudiesMagnetic Resonance Imaging, CineHeart FailureHumansMaleFemaleAgedTreatment OutcomeMiddle AgedVentricular Dysfunction, LeftReproducibility of Results

Stichwörter der Autor:innen

cardiac MRIcardiac resynchronization therapyimagingventricular function

Autor:innen und Institutionen

  • Department of Advanced Biomedical Sciences, Federico II University of Naples, Naples, Italy.
  • Division of Cardiology, Department of Medicine, Karolinska Institutet, Stockholm, Sweden.
  • Clinica Villa dei Fiori, Advanced Cardiovascular Imaging Unit, Acerra, Naples, Italy.
  • Department of Medical, Motor and Wellness Sciences, Parthenope University of Naples, Naples, Italy.
  • Clinical Unit, Biotronik Italia S.p.a., Cologno Monzese, Italy.

ORCID-Profile: Christian Basile, Costantino Mancusi

Zitieren

APA

Basile, C., Scatteia, A., Giacopelli, D., Gallo, P., Pezzullo, S., Mancusi, C., Pascale, C. E., Gargiulo, P., Marzano, F., Perrone-Filardi, P., Paolillo, S., & Dellegrottaglie, S. (2024). Feasibility of a Cardiac Magnetic Resonance Protocol for “off‐on” Cardiac Resynchronization Therapy Evaluation. Echocardiography. https://doi.org/10.1111/echo.70003

Vancouver

Basile C, Scatteia A, Giacopelli D, Gallo P, Pezzullo S, Mancusi C, et al. Feasibility of a Cardiac Magnetic Resonance Protocol for “off‐on” Cardiac Resynchronization Therapy Evaluation. Echocardiography. 2024. doi:10.1111/echo.70003

BibTeX
@article{Basile2024,
  author = {Basile, Christian and Scatteia, Alessandra and Giacopelli, Daniele and Gallo, Paolo and Pezzullo, Salvatore and Mancusi, Costantino and Pascale, Carmine E and Gargiulo, Paola and Marzano, Federica and Perrone-Filardi, Pasquale and Paolillo, Stefania and Dellegrottaglie, Santo},
  title = {Feasibility of a Cardiac Magnetic Resonance Protocol for “off‐on” Cardiac Resynchronization Therapy Evaluation},
  journal = {Echocardiography},
  year = {2024},
  doi = {10.1111/echo.70003}
}
Kostenlos starten →