Beobachtungsstudie in Echocardiography, 2024. Written by Helge Skulstad and 5 co-authors. Institution: Department of Cardiology, Oslo University Hospital, Rikshospitalet, Oslo, Norway. Major MEDLINE topics: Transcatheter Aortic Valve Replacement, Global Longitudinal Strain, Ventricular Remodeling, Aortic Valve Stenosis. Cited 4 times so far (Crossref); 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: European Association of Cardiovascular Imaging.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

Introduction

Oslo University Hospital is a tertiary center conducting a significant number of transcatheter aortic valve implantation (TAVI) procedures per year. In this follow‐up MediPace study, we aimed to investigate early echocardiographic changes in systolic and diastolic functions after TAVI in these patients.

Methods

All patients enrolled in the previous study were contacted 3 months after TAVI for echocardiographic evaluation. Detailed echocardiography was performed 3.5 ± 1.6 months after TAVI, and compared with baseline evaluations.

Results

A total of 101 patients were analyzed. Mean age was 80.1 ± 6.8 years and 40% of the patients were female. We observed a significant improvement in global longitudinal strain (GLS) (pre‐TAVI −16.8 ± 4.1%, post‐TAVI −17.8 ± 3.6%, p < .001), with no notable change in LVEF. More than half of the patients (52%) experienced a significant reverse remodeling with ≥10% decrease in left ventricular mass index (LVMi) following TAVI (pre‐TAVI 123.6 ± 32.1 vs. 109.7 ± 28.9 g/m 2 post‐TAVI, p < .001). Pre‐TAVI LVMi was a positive predictor, whereas history of HT was a negative predictor of LVMi reduction. There was no significant improvement in diastolic function following TAVI. Highest degree of paravalvular leakage was mild to moderate and was observed in only 2%.

Conclusions

A significant improvement in GLS and LVMi was found following TAVI. History of hypertension and baseline LVMi were predictors of LVMi change. There was no notable change in diastolic function, including left atrial strain.

Subjects

MeSH terms (MEDLINE)

Transcatheter Aortic Valve ReplacementGlobal Longitudinal StrainVentricular RemodelingAortic Valve StenosisHumansFemaleAgedAged, 80 and overHypertensionEchocardiographyProspective StudiesSystoleDiastole

Author keywords

TAVIleft atrial strainleft ventricular mass indexreverse remodelingstrain echocardiography

Authors and institutions

  • Department of Cardiology, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
  • Institute for Surgical Research, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
  • ProCardio Center for Innovation, Clinic of Heart-, Lung- and Vascular Diseases, Oslo University Hospital, Rikshospitalet, Oslo, Norway.
  • Institute of Clinical Medicine, University of Oslo, All Oslo, Norway.

ORCID profiles: Esra Kaya

Funding

  • European Association of Cardiovascular Imaging

Cite

APA

Skulstad, H., Andresen, K., Aaberge, L., Haugaa, K. H., Edvardsen, T., & Kaya, E. (2024). Early reverse remodeling by echocardiography after transcatheter aortic valve implantation. Echocardiography. https://doi.org/10.1111/echo.15865

Vancouver

Skulstad H, Andresen K, Aaberge L, Haugaa KH, Edvardsen T, Kaya E. Early reverse remodeling by echocardiography after transcatheter aortic valve implantation. Echocardiography. 2024. doi:10.1111/echo.15865

BibTeX
@article{Skulstad2024,
  author = {Skulstad, Helge and Andresen, K and Aaberge, Lars and Haugaa, Kristina H and Edvardsen, Thor and Kaya, Esra},
  title = {Early reverse remodeling by echocardiography after transcatheter aortic valve implantation},
  journal = {Echocardiography},
  year = {2024},
  doi = {10.1111/echo.15865}
}
Start for free →