Impaired longitudinal systolic–diastolic coupling and cardiac response to exercise in patients with hypertrophic cardiomyopathy
Echocardiography · 2024
DOI: 10.1111/echo.15857 ↗At a glance
Journal article in Echocardiography, 2024. Written by James P MacNamara and 11 co-authors. Institution: Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Dallas, Dallas, Texas, USA. Major MEDLINE topics: Cardiomyopathy, Hypertrophic, Diastole, Exercise Test, Stroke Volume. Cited 4 times so far (Crossref); 38 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: NIH HHS, Fichtenbaum Charitable Trust, NHLBI NIH HHS.
Abstract (original language)
Background
In patients with hypertrophic cardiomyopathy (HCM), impaired augmentation of stroke volume and diastolic dysfunction contribute to exercise intolerance. Systolic–diastolic (S‐D) coupling characterizes how systolic contraction of the left ventricle (LV) primes efficient elastic recoil during early diastole. Impaired S‐D coupling may contribute to the impaired cardiac response to exercise in patients with HCM.
Methods
Patients with HCM ( n = 25, age = 47 ± 9 years) and healthy adults ( n = 115, age = 49 ± 10 years) underwent a cardiopulmonary exercise testing (CPET) and echocardiogram. S‐D coupling was defined as the ratio of LV longitudinal excursion of the mitral annulus during early diastole (ED exc ) and systole ( S exc ) and compared between groups. Peak oxygen uptake (peak V̇O 2 ) (Douglas bags), cardiac index (C 2 H 2 rebreathe), and stroke volume index (SVi) were assessed during CPET. Linear regression was performed between S‐D coupling and peak V̇O 2 , peak cardiac index, and peak SVi.
Results
S‐D coupling was lower in HCM (Controls: 0.63 ± 0.08, HCM: 0.56 ± 0.10, p < 0.001). Peak V̇O 2 and stroke volume reserve were lower in patients with HCM (Peak VO 2 Controls: 28.5 ± 5.5, HCM: 23.7 ± 7.2 mL/kg/min, p < 0.001, SV reserve: Controls 39 ± 16, HCM 30 ± 18 mL, p = 0.008). In patients with HCM, S‐D coupling was associated with peak V̇O 2 ( r = 0.47, p = 0.018), peak cardiac index ( r = 0.60, p = 0.002), and peak SVi ( r = 0.63, p < 0.001).
Conclusion
Systolic–diastolic coupling was impaired in patients with HCM and was associated with fitness and the cardiac response to exercise. Inefficient S‐D coupling may link insufficient stroke volume generation, diastolic dysfunction, and exercise intolerance in HCM.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Dallas, Dallas, Texas, USA.
- Department of Internal Medicine, Division of Cardiovascular Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
ORCID profiles: James P MacNamara, Denis J Wakeham
Funding
- NIH HHS
- Fichtenbaum Charitable Trust
- NHLBI NIH HHS
- NIA NIH HHS
- American College of Sports Medicine
- American Heart Association
- National Institutes of Health
Cite
APA
MacNamara, J. P., Turlington, W. M., Dias, K. A., Hearon, C. M., Ivey, E., Delgado, V. A., Brazile, T. L., Wakeham, D. J., Turer, A. T., Link, M. S., Levine, B. D., & Sarma, S. (2024). Impaired longitudinal systolic–diastolic coupling and cardiac response to exercise in patients with hypertrophic cardiomyopathy. Echocardiography. https://doi.org/10.1111/echo.15857
Vancouver
MacNamara JP, Turlington WM, Dias KA, Hearon CM, Ivey E, Delgado VA, et al. Impaired longitudinal systolic–diastolic coupling and cardiac response to exercise in patients with hypertrophic cardiomyopathy. Echocardiography. 2024. doi:10.1111/echo.15857
BibTeX
@article{MacNamara2024,
author = {MacNamara, James P and Turlington, William M and Dias, Katrin A and Hearon, Christopher M and Ivey, Erika and Delgado, Vincent A and Brazile, Tiffany L and Wakeham, Denis J and Turer, Aslan T and Link, Mark S and Levine, Benjamin D and Sarma, Satyam},
title = {Impaired longitudinal systolic–diastolic coupling and cardiac response to exercise in patients with hypertrophic cardiomyopathy},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.15857}
}
EUVIMED