Doppler‐derived pulmonary pulse transit time measurements in chronic obstructive pulmonary disease: Reproducibility and cardiopulmonary function
Echocardiography · 2024
DOI: 10.1111/echo.15821 ↗At a glance
Journal article in Echocardiography, 2024. Written by Friederike Löffler and 9 co-authors. Institution: Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany. Major MEDLINE topics: Pulmonary Disease, Chronic Obstructive, Pulse Wave Analysis, Echocardiography, Doppler. Cited 2 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Topics: COPD
Abstract (original language)
Introduction
Doppler‐derived pulmonary pulse transit time (pPTT) is an auspicious hemodynamic marker in chronic pulmonary diseases. The aim is to compare four distinct pPTT measurements and its relation to right cardiac and pulmonary function.
Methods
Prospectively, 25 chronic obstructive pulmonary disease (COPD) patients (four patients excluded) and 32 healthy subjects underwent repeated distinct pPTT measurements, standard echocardiography, and pulmonary function testing on the same day. pPTT was defined as the interval from the R or Q‐wave in the electrocardiogram to the corresponding pulse wave Doppler peak late systolic (S) 2 or diastolic (D) pulmonary vein flow velocity (pPTT R‐S, Q‐S, R‐D, Q‐D). Reproducibility was assessed using Bland–Altman analysis, coefficient of variation (COV), intraclass correlation coefficient (ICC), and power calculations. Associations with right ventricular RV tissue and pulse wave Doppler velocities (RV E', RV S', RV A', RV E, RV A, RV E/E', RV E/A), TAPSE, right ventricular fractional area change, left ventricular systolic and diastolic function (LV ejection fraction, E, A, E/A, E/E', septal E', lateral E'), LA diameters, as well as forced expiratory volume in 1 s, forced vital capacity (FVC) predicted (%), and in liters were analyzed.
Results
There was no significant difference and no bias between pPTT measures ( p range: .1–.9). COV was in COPD 1.2%–2.3%, in healthy subjects 1.0%–3.1%. ICC ranged from .92 (COPD) to .96 (healthy subjects). In COPD significant correlations were found for pPTT R‐S , Q‐S and R‐D with RV E`, (all > ρ : .49, < p = .0364), pPTT R‐S, Q‐S with RV E/E` (both > ρ : .49, < p = .0291), pPTT Q‐S with RV S´ ( ρ : .58, p = .0134), RV A ( ρ : .59, p = .0339) and heart rate > ρ : −.39, < p = .0297). pPTT R‐S, R‐D showed significant correlations with FVC predicted (%) ( ρ : .48 p = .0224) and FVC (l) ( ρ :.47 p = .0347).
Conclusions
All pPTT measures exhibited high reproducibility. In COPD patients pPTT measures correlate with diastolic right ventricular function. Defining Q as starting point seems clinically advantageous considering electromechanical desynchrony in patients with conduction disorders.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany.
- Department of Pneumology, Hannover Medical School, Hannover, Germany.
- Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hannover, Germany.
- Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany.
ORCID profiles: Friederike Löffler
Cite
APA
Löffler, F., Westhoff-Bleck, M., Welte, T., Park, D. H., Olsson, K. M., Behrendt, L., Klimeš, F., Bauersachs, J., Wacker, F., & Pöhler, G. H. (2024). Doppler‐derived pulmonary pulse transit time measurements in chronic obstructive pulmonary disease: Reproducibility and cardiopulmonary function. Echocardiography. https://doi.org/10.1111/echo.15821
Vancouver
Löffler F, Westhoff-Bleck M, Welte T, Park DH, Olsson KM, Behrendt L, et al. Doppler‐derived pulmonary pulse transit time measurements in chronic obstructive pulmonary disease: Reproducibility and cardiopulmonary function. Echocardiography. 2024. doi:10.1111/echo.15821
BibTeX
@article{Lffler2024,
author = {Löffler, Friederike and Westhoff-Bleck, Mechthild and Welte, Tobias and Park, Da-Hee and Olsson, Karen M and Behrendt, Lea and Klimeš, Filip and Bauersachs, Johann and Wacker, Frank and Pöhler, Gesa Helen},
title = {Doppler‐derived pulmonary pulse transit time measurements in chronic obstructive pulmonary disease: Reproducibility and cardiopulmonary function},
journal = {Echocardiography},
year = {2024},
doi = {10.1111/echo.15821}
}
EUVIMED