EUVIMEDEUVIMED entdecken
Systematische ÜbersichtOpen Access · CC BY-NC 4.0

Improving accuracy in diagnosing aortic stenosis severity: An in‐depth analysis of echocardiographic measurement error through literature review and simulation study

Bart J J Velders iD, Rolf H H Groenwold, Nina Ajmone Marsan, Arie-Pieter Kappetein, Rob A F De Lind Van Wijngaarden, Jerry Braun, Robert J M Klautz, Michiel D Vriesendorp

Echocardiography · 2023

DOI: 10.1111/echo.15664 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Echocardiography, 2023. Verfasst von Bart J J Velders und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands. Hauptthemen laut MEDLINE: Aortic Valve Stenosis. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 103 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The present guidelines advise replacing the aortic valve for individuals with severe aortic stenosis (AS) based on various echocardiographic parameters. Accurate measurements are essential to avoid misclassification and unnecessary interventions. The objective of this study was to evaluate the influence of measurement error on the echocardiographic evaluation of the severity of AS. Methods and results A systematic review was performed to examine whether measurement errors are reported in studies focusing on the prognostic value of peak aortic jet velocity (V max ), mean pressure gradient (MPG), and effective orifice area (EOA) in asymptomatic patients with AS. Out of the 37 studies reviewed, 17 (46%) acknowledged the existence of measurement errors, but none of them utilized methods to address them. Secondly, the magnitude of potential errors was collected from available literature for use in clinical simulations. Interobserver variability ranged between 0.9% and 8.3% for V max and MPG but was higher for EOA (range 7.7%‐12.7%), indicating lower reliability. Assuming a circular left ventricular outflow tract area led to a median underestimation of EOA by 23% compared to planimetry by other modalities. A clinical simulation resulted in the reclassification of 42% of patients, shifting them from a diagnosis of severe AS to moderate AS.

Conclusions

Measurement errors are underreported in studies on echocardiographic assessment of AS severity. These errors can lead to misclassification and misdiagnosis. Clinicians and scientists should be aware of the implications for accurate clinical decision‐making and assuring research validity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Valve StenosisHumansReproducibility of ResultsEchocardiographyAortic ValveStroke VolumeSeverity of Illness Index

Stichwörter der Autor:innen

aortic stenosisechocardiographymisclassificationrandom/systematic measurement error

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands.
  • Department of Clinical Epidemiology, Leiden University Medical Center, Leiden, The Netherlands.
  • Department of Biomedical Data Science, Leiden University Medical Center, Leiden, The Netherlands.
  • Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands.
  • Global Clinical Operations, Coronary and Structural Heart, Medtronic, Maastricht, The Netherlands.
  • Department of Cardiothoracic Surgery, Amsterdam UMC Location AMC, Amsterdam, The Netherlands.

ORCID-Profile: Bart J J Velders

Zitieren

APA

Velders, B. J. J., Groenwold, R. H. H., Ajmone Marsan, N., Kappetein, A. P., Wijngaarden, R. A. F. L. V., Braun, J., Klautz, R. J. M., & Vriesendorp, M. D. (2023). Improving accuracy in diagnosing aortic stenosis severity: An in‐depth analysis of echocardiographic measurement error through literature review and simulation study. Echocardiography. https://doi.org/10.1111/echo.15664

Vancouver

Velders BJJ, Groenwold RHH, Ajmone Marsan N, Kappetein AP, Wijngaarden RAFLV, Braun J, et al. Improving accuracy in diagnosing aortic stenosis severity: An in‐depth analysis of echocardiographic measurement error through literature review and simulation study. Echocardiography. 2023. doi:10.1111/echo.15664

BibTeX
@article{Velders2023,
  author = {Velders, Bart J J and Groenwold, Rolf H H and Ajmone Marsan, Nina and Kappetein, Arie-Pieter and Wijngaarden, Rob A F De Lind Van and Braun, Jerry and Klautz, Robert J M and Vriesendorp, Michiel D},
  title = {Improving accuracy in diagnosing aortic stenosis severity: An in‐depth analysis of echocardiographic measurement error through literature review and simulation study},
  journal = {Echocardiography},
  year = {2023},
  doi = {10.1111/echo.15664}
}
Kostenlos starten →