Effects of morphological characteristics of patent foramen ovale by transesophageal echocardiography on minimalist transcatheter closure in southern China
Echocardiography · 2023
DOI: 10.1111/echo.15629 ↗Kurz gefasst
Fachartikel in der Zeitschrift Echocardiography, 2023. Verfasst von Shushan Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, The Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai, China. Hauptthemen laut MEDLINE: Foramen Ovale, Patent, Atrial Septum. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben.
Abstract (Originalsprache)
Objectives
Transcatheter closure has become one of the main treatment methods for patent foramen ovale (PFO). However, the population in southern China is generally thin and the size of PFO is small, so the application of minimalist surgery is challenging. This study aimed to analyze the morphological characteristics of PFOs in southern China by transesophageal echocardiography (TEE), and to explore the influence on minimalist transcatheter closure.
Methods
About 110 patients with PFO closure in our hospital were selected. All cases were examined by TEE including the PFO size, length, septum secundum thickness, color characteristic and surrounding structures, and morphologically classified. During the operation, the procedure time, number of times for the guidewire attempting to pass the interatrial septum and the success rate of simply using J guidewire to cross the interatrial septum were recorded.
Results
About 110 cases of PFO were classified into two categories and four subtypes, including 55 cases with Uniform Channel Type (UCT, 50.0%), 16 cases with Irregular Channel Type (ICT, 14.6%), 15 cases with Right Funnel Type (RFT, 13.6%), and 24 cases with Left Funnel Type (LFT, 21.8%). According to the complexity of the procedure, they were divided into simple procedure ( n = 73) and complex procedure ( n = 37). Multivariate logistic regression showed that the anatomical types of PFO, the tunnel entrance size, and the tunnel entrance size
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, The Fifth Affiliated Hospital of Sun Yat-sen University, Zhuhai, China.
ORCID-Profile: Xiaobo Chen
Zitieren
APA
Zhang, S., Gao, Z., Chen, H., Pi, S., Wu, C., He, K., & Chen, X. (2023). Effects of morphological characteristics of patent foramen ovale by transesophageal echocardiography on minimalist transcatheter closure in southern China. Echocardiography. https://doi.org/10.1111/echo.15629
Vancouver
Zhang S, Gao Z, Chen H, Pi S, Wu C, He K, et al. Effects of morphological characteristics of patent foramen ovale by transesophageal echocardiography on minimalist transcatheter closure in southern China. Echocardiography. 2023. doi:10.1111/echo.15629
BibTeX
@article{Zhang2023,
author = {Zhang, Shushan and Gao, Ziqing and Chen, Hui and Pi, Songying and Wu, Chaoqun and He, Kunyan and Chen, Xiaobo},
title = {Effects of morphological characteristics of patent foramen ovale by transesophageal echocardiography on minimalist transcatheter closure in southern China},
journal = {Echocardiography},
year = {2023},
doi = {10.1111/echo.15629}
}
EUVIMED