Cost–utility analysis of a flash continuous glucose monitoring system in the management of people with type 2 diabetes mellitus on basal insulin therapy—An Italian healthcare system perspective
Diabetes, Obesity and Metabolism · 2024
DOI: 10.1111/dom.15703 ↗Kurz gefasst
Fachartikel in der Zeitschrift Diabetes, Obesity and Metabolism, 2024. Verfasst von Stefano Del Prato und 3 weiteren Autor:innen. Beteiligte Einrichtung: Interdisciplinary Research Center "Health Science" of the Sant'Anna School of Advanced Studies, Pisa, Italy. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 2, Cost-Benefit Analysis, Blood Glucose Self-Monitoring, Quality-Adjusted Life Years. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 49 Literaturangaben.
Themen: Diabetes mellitus
Abstract (Originalsprache)
Aims
To assess the cost–utility of the FreeStyle Libre flash continuous glucose monitoring (CGM) system from an Italian healthcare system perspective, when compared with self‐monitoring of blood glucose (SMBG) in people living with type 2 diabetes mellitus (T2DM) receiving basal insulin. Materials and Methods A patient‐level microsimulation model was run using Microsoft Excel for 10 000 patients over a lifetime horizon, with 3.0% discounting for costs and utilities. Inputs were based on clinical trials and real‐world evidence, with patient characteristics reflecting Italian population data. The effect of flash CGM was modelled as a persistent 0.8% reduction in glycated haemoglobin versus SMBG. Costs (€ 2023) and disutilities were applied to glucose monitoring, diabetes complications, severe hypoglycaemia, and diabetic ketoacidosis. The health outcome was measured as quality‐adjusted life‐years (QALYs).
Results
Direct costs were €5338 higher with flash CGM than with SMBG. Flash CGM was associated with 0.51 more QALYs than SMBG, giving an incremental cost‐effectiveness ratio (ICER) of €10 556/QALY. Scenario analysis ICERs ranged from €3825/QALY to €26 737/QALY. In probabilistic analysis, flash CGM was 100% likely to be cost effective at willingness‐to‐pay thresholds > €20 000/QALY.
Conclusions
From an Italian healthcare system perspective, flash CGM is cost effective compared with SMBG for people living with T2DM on basal insulin.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Interdisciplinary Research Center "Health Science" of the Sant'Anna School of Advanced Studies, Pisa, Italy.
- Department of Precision and Regenerative Medicine and Ionian Area, University of Bari Aldo Moro, Bari, Italy.
- Eversana, Burlington, Ontario, Canada.
- Abbott Diabetes Care, Alameda, California, USA.
ORCID-Profile: Francesco Giorgino, Yeesha Poon
Zitieren
APA
Del Prato, S., Giorgino, F., Szafranski, K., & Poon, Y. (2024). Cost–utility analysis of a flash continuous glucose monitoring system in the management of people with type 2 diabetes mellitus on basal insulin therapy—An Italian healthcare system perspective. Diabetes, Obesity and Metabolism. https://doi.org/10.1111/dom.15703
Vancouver
Del Prato S, Giorgino F, Szafranski K, Poon Y. Cost–utility analysis of a flash continuous glucose monitoring system in the management of people with type 2 diabetes mellitus on basal insulin therapy—An Italian healthcare system perspective. Diabetes, Obesity and Metabolism. 2024. doi:10.1111/dom.15703
BibTeX
@article{DelPrato2024,
author = {Del Prato, Stefano and Giorgino, Francesco and Szafranski, Kirk and Poon, Yeesha},
title = {Cost–utility analysis of a flash continuous glucose monitoring system in the management of people with type 2 diabetes mellitus on basal insulin therapy—An Italian healthcare system perspective},
journal = {Diabetes, Obesity and Metabolism},
year = {2024},
doi = {10.1111/dom.15703}
}
EUVIMED