Current insulin infusion set failure criteria may be too stringent for real‐life settings and may skew infusion set failure outcomes in extended‐wear infusion set studies
Diabetes, Obesity and Metabolism · 2023-04 · 25 (4) · 1106-1111
DOI: 10.1111/dom.14935 ↗At a glance
Journal article in Diabetes, Obesity and Metabolism, published online on 2022-12-23. Written by Jasmin R Kastner and 8 co-authors. Institution: Capillary Biomedical Inc, Irvine, California, USA. Major MEDLINE topics: Insulin, Diabetes Mellitus, Type 1. Cited 1 times so far (Crossref); 12 references. The full text is freely available (open access, CC BY-NC-ND 4.0). Funded by: Leona M. and Harry B. Helmsley Charitable Trust.
Abstract (original language)
Currently, there is a trend toward developing extended-wear insulin infusion sets (Ex-IISs) to continuously infuse insulin subcutaneously for 7 days or longer. Replacing an insulin infusion set (IIS) every 2 to 3 days is costly as well as tedious and increases the risk of loss of potent infusion sites. Little is known about the ideal design of human trials of Ex-IISs, and researchers have limited experience of testing device survival rates beyond 3 days of use. In 2013, a team at Stanford University introduced a set of infusion set failure (ISF) criteria, which have been adopted with minimal modifications by subsequent IIS studies. According to these ISF criteria, an IIS is to be replaced if one of the following occurs:
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Capillary Biomedical Inc, Irvine, California, USA.
- Medical University of Graz, Division of Endocrinology and Diabetology, Graz, Austria.
ORCID profiles: Jasmin R Kastner, Julia K Mader
Funding
- Leona M. and Harry B. Helmsley Charitable Trust
Cite
APA
Kastner, J. R., Poettler, T., Kopanz, J., Hochfellner, D. A., Romey, M., Baumann, P. M., Muchmore, D., Strasma, P. J., & Mader, J. K. (2023). Current insulin infusion set failure criteria may be too stringent for real‐life settings and may skew infusion set failure outcomes in extended‐wear infusion set studies. Diabetes, Obesity and Metabolism, 25(4), 1106-1111. https://doi.org/10.1111/dom.14935
Vancouver
Kastner JR, Poettler T, Kopanz J, Hochfellner DA, Romey M, Baumann PM, et al. Current insulin infusion set failure criteria may be too stringent for real‐life settings and may skew infusion set failure outcomes in extended‐wear infusion set studies. Diabetes, Obesity and Metabolism. 2023;25(4):1106-1111. doi:10.1111/dom.14935
BibTeX
@article{Kastner2023,
author = {Kastner, Jasmin R and Poettler, Tina and Kopanz, Julia and Hochfellner, Daniel A and Romey, Matt and Baumann, Petra M and Muchmore, Douglas and Strasma, Paul J and Mader, Julia K},
title = {Current insulin infusion set failure criteria may be too stringent for real‐life settings and may skew infusion set failure outcomes in extended‐wear infusion set studies},
journal = {Diabetes, Obesity and Metabolism},
year = {2023},
volume = {25},
number = {4},
pages = {1106--1111},
doi = {10.1111/dom.14935}
}
EUVIMED