Experiences with Simplera sync™ all‐in‐one sensors and extended wear infusion sets in adolescents and young adults using the MiniMed ™ 780G : A qualitative study
Diabetic Medicine · 2026-03 · 43 (3)
DOI: 10.1111/dme.70197 ↗Kurz gefasst
Qualitative Studie in der Zeitschrift Diabetic Medicine, online erschienen am 29.12.2025. Verfasst von Venus R Michaels und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Paediatrics and Child Health, University of Otago, Dunedin, New Zealand. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Blood Glucose Self-Monitoring, Insulin Infusion Systems, Insulin. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 24 Literaturangaben. Gefördert von: Lions Clubs New Zealand, Starship Foundation, University of Otago.
Abstract (Originalsprache)
Aims
To evaluate the real‐world user experience of young people (7–25 years) with type 1 diabetes and previously very elevated glycaemia (≥69 mmol/mol) transitioning from the MiniMed™ 780G advanced hybrid closed‐loop (AHCL) system with Guardian™ 4 continuous glucose monitoring systems (CGM) and 3‐day infusion sets to the upgraded system with Simplera Sync™ all‐in‐one CGM and 7‐day Extended™ wear infusion sets (EIS).
Methods
Qualitative interviews were conducted with 11 participants from the CO‐PILOT trial extension phase who had used the upgraded system for at least 4 weeks. Thematic analysis was used to identify aspects of the technology transition that reduced, continued, or did not affect the burden of diabetes care and technology.
Results
Participants reported several burden‐reducing aspects of the upgraded system, including easier, independent insertion of both sensors and infusion sets, improved device design (slimmer profile, one‐piece disposable design), reduced frequency of equipment changes, and decreased psychosocial burden. Aspects with ongoing burden included premature sensor failures, connection issues between pump and sensor, adhesion problems, and concerns about alarm functionality. Trust in the AHCL system remained high across both systems for most participants.
Conclusion
The transition from Guardian™ 4 and 3‐day infusion sets to Simplera Sync™ and EIS was overall positive, with participants reporting enhanced user experience, greater convenience, and improved autonomy. However, challenges with premature sensor failure and alarm functionality were identified at times. These findings highlight the importance of continued technological advancement while maintaining multiple options to accommodate individual needs and preferences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Paediatrics and Child Health, University of Otago, Dunedin, New Zealand.
- School of Health Equity and Innovation, Division of Health, University of Waikato, Hamilton, New Zealand.
- Guangdong Provincial Key Laboratory of Diabetology, The Third Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.
- Waikato Medical Research Centre, University of Waikato, Hamilton, New Zealand.
- Waikato Regional Diabetes Service, Te Whatu Ora Waikato, Hamilton, New Zealand.
- Department of Paediatrics and Child Health, University of Otago, Wellington, New Zealand.
ORCID-Profile: Venus R Michaels, Hamish R Crocket, Alisa Boucsein, Yongwen Zhou, Ryan G Paul, Esko Wiltshire, Craig Jefferies, Martin I de Bock, Benjamin J Wheeler
Förderung
- Lions Clubs New Zealand
- Starship Foundation
- University of Otago
- Lotto New Zealand
- Otago Southland Diabetes Research Trust
- Spinal Cord Society of New Zealand
- Bowen Family Foundation
Zitieren
APA
Michaels, V. R., Crocket, H. R., Boucsein, A., Zhou, Y., Paul, R. G., Wiltshire, E., Jefferies, C., de Bock, M. I., & Wheeler, B. J. (2026). Experiences with Simplera sync™ all‐in‐one sensors and extended wear infusion sets in adolescents and young adults using the MiniMed ™ 780G : A qualitative study. Diabetic Medicine, 43(3). https://doi.org/10.1111/dme.70197
Vancouver
Michaels VR, Crocket HR, Boucsein A, Zhou Y, Paul RG, Wiltshire E, et al. Experiences with Simplera sync™ all‐in‐one sensors and extended wear infusion sets in adolescents and young adults using the MiniMed ™ 780G : A qualitative study. Diabetic Medicine. 2026;43(3). doi:10.1111/dme.70197
BibTeX
@article{Michaels2026,
author = {Michaels, Venus R and Crocket, Hamish R and Boucsein, Alisa and Zhou, Yongwen and Paul, Ryan G and Wiltshire, Esko and Jefferies, Craig and de Bock, Martin I and Wheeler, Benjamin J},
title = {Experiences with Simplera sync™ all‐in‐one sensors and extended wear infusion sets in adolescents and young adults using the MiniMed ™ 780G : A qualitative study},
journal = {Diabetic Medicine},
year = {2026},
volume = {43},
number = {3},
doi = {10.1111/dme.70197}
}
EUVIMED