Comparative Performance of Image‐Enhanced Endoscopy for Adenoma and Sessile Serrated Lesion Detection: A Network Meta‐Analysis
Digestive Endoscopy · 2026
DOI: 10.1111/den.70262 ↗Kurz gefasst
Netzwerk-Metaanalyse in der Zeitschrift Digestive Endoscopy, 2026. Verfasst von Satoshi Shinozaki und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shinozaki Medical Clinic, Utsunomiya, Japan. Hauptthemen laut MEDLINE: Image Enhancement, Adenoma, Colonic Polyps, Colorectal Neoplasms. Die Arbeit nennt 71 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background and Aims Image‐enhanced endoscopy (IEE) technologies have been developed to improve colorectal polyp detection, but their comparative efficacy remains uncertain. We performed a network meta‐analysis to compare the efficacy of major IEE modalities on colorectal polyp detection.
Methods
We searched MEDLINE, Embase, and CENTRAL for randomized controlled trials comparing seven IEE modalities (autofluorescence imaging, blue‐light imaging, flexible spectral imaging color enhancement, i‐scan, linked color imaging [LCI], narrow band imaging [NBI], and texture and color enhancement imaging [TXI]) with white‐light imaging (WLI). The primary outcome was the comparison of performance of IEE systems in adenoma detection rate (ADR); the secondary outcome was sessile serrated lesion detection rate (SSLDR). We estimated the number needed to screen (NNS) with 95% credible intervals (CrIs). Study credibility was assessed using the Confidence in Network Meta‐analysis (CINeMA) framework.
Results
Fifty‐three randomized controlled trials encompassing 34,364 patients were included. Compared with WLI, moderate‐confidence evidence supported improvements in ADR with TXI (NNS 13, 95% CrIs 7–32), LCI (NNS 17, 95% CrIs 11–31), and NBI (NNS 35, 95% CrIs 18–139), whereas low‐confidence evidence supported benefits for i‐scan (NNS 7, 95% CrIs 3–18). Direct comparison across IEEs demonstrated little‐to‐no clinically meaningful differences in ADR. For SSLDR, moderate‐confidence evidence supported improvements with LCI (NNS 29, 95% CrIs 15–96) and NBI (NNS 38, 95% CrIs 19–143) compared with WLI.
Conclusions
LCI demonstrated the most robust and reproducible performance across multiple analyses with moderate‐confidence evidence, although differences among IEE modalities were generally modest.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shinozaki Medical Clinic, Utsunomiya, Japan.
- Division of Gastroenterology, Department of Medicine, Jichi Medical University, Shimotsuke, Japan.
- Division of Gastroenterological, General and Transplant Surgery, Department of Surgery, Jichi Medical University, Shimotsuke, Japan.
- Division of Community and Family Medicine, Jichi Medical University, Shimotsuke-City, Japan.
- Division of Gastroenterology and Farncombe Family Digestive Health Research Institute, Department of Medicine, McMaster University, Hamilton, Ontario, Canada.
Zitieren
APA
Shinozaki, S., Watanabe, J., & Yano, T. (2026). Comparative Performance of Image‐Enhanced Endoscopy for Adenoma and Sessile Serrated Lesion Detection: A Network Meta‐Analysis. Digestive Endoscopy. https://doi.org/10.1111/den.70262
Vancouver
Shinozaki S, Watanabe J, Yano T. Comparative Performance of Image‐Enhanced Endoscopy for Adenoma and Sessile Serrated Lesion Detection: A Network Meta‐Analysis. Digestive Endoscopy. 2026. doi:10.1111/den.70262
BibTeX
@article{Shinozaki2026,
author = {Shinozaki, Satoshi and Watanabe, Jun and Yano, Tomonori},
title = {Comparative Performance of Image‐Enhanced Endoscopy for Adenoma and Sessile Serrated Lesion Detection: A Network Meta‐Analysis},
journal = {Digestive Endoscopy},
year = {2026},
doi = {10.1111/den.70262}
}
EUVIMED