Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: a real-time comparison with screening endoscopists
Endoscopy · 01.08.2023 · 55 (08) · 756-765
DOI: 10.1055/a-2009-3990 ↗Kurz gefasst
Klinische Studie in der Zeitschrift Endoscopy, erschienen am 01.08.2023. Verfasst von Britt B S L Houwen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Amsterdam University Medical Center, Amsterdam, the Netherlands. Hauptthemen laut MEDLINE: Colonic Polyps, Colorectal Neoplasms, Adenoma. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: UP-18-00565, TKI 18-01, NA.
Abstract (Originalsprache)
Background
We aimed to compare the accuracy of the optical diagnosis of diminutive colorectal polyps, including sessile serrated lesions (SSLs), between a computer-aided diagnosis (CADx) system and endoscopists during real-time colonoscopy.
Methods
We developed the POLyp Artificial Recognition (POLAR) system, which was capable of performing real-time characterization of diminutive colorectal polyps. For pretraining, the Microsoft-COCO dataset with over 300 000 nonpolyp object images was used. For training, eight hospitals prospectively collected 2637 annotated images from 1339 polyps (i. e. publicly available online POLAR database). For clinical validation, POLAR was tested during colonoscopy in patients with a positive fecal immunochemical test (FIT), and compared with the performance of 20 endoscopists from eight hospitals. Endoscopists were blinded to the POLAR output. Primary outcome was the comparison of accuracy of the optical diagnosis of diminutive colorectal polyps between POLAR and endoscopists (neoplastic [adenomas and SSLs] versus non-neoplastic [hyperplastic polyps]). Histopathology served as the reference standard.
Results
During clinical validation, 423 diminutive polyps detected in 194 FIT-positive individuals were included for analysis (300 adenomas, 41 SSLs, 82 hyperplastic polyps). POLAR distinguished neoplastic from non-neoplastic lesions with 79 % accuracy, 89 % sensitivity, and 38 % specificity. The endoscopists achieved 83 % accuracy, 92 % sensitivity, and 44 % specificity. The optical diagnosis accuracy between POLAR and endoscopists was not significantly different (P = 0.10). The proportion of polyps in which POLAR was able to provide an optical diagnosis was 98 % (i. e. success rate).
Conclusions
We developed a CADx system that differentiated neoplastic from non-neoplastic diminutive polyps during endoscopy, with an accuracy comparable to that of screening endoscopists and near-perfect success rate.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Amsterdam University Medical Center, Amsterdam, the Netherlands.
- Department of Gastroenterology and Hepatology, Radboud University Nijmegen Medical Center, Radboud University of Nijmegen, Nijmegen, The Netherlands.
- ZiuZ Visual Intelligence, Gorredijk, the Netherlands.
- Department of Gastroenterology and Hepatology, Subdivision Statistics, Amsterdam University Medical Center, Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands.
- Department of Gastroenterology and Hepatology, Medical Center Leeuwarden, Leeuwarden, The Netherlands.
- Bergman Clinics Maag and Darm Amsterdam, Amsterdam, The Netherlands.
ORCID-Profile: Britt B S L Houwen, Evelien Dekker
Förderung
- UP-18-00565
- TKI 18-01
- NA
- the European Regional Development Fund region Northern-Netherlands
- PPP Allowance made available by Health~Holland, Top Sector Life Sciences & Health, to the Dutch Digestive Disease Foundation to stimulate public-private partne…
- The province of Friesland
Zitieren
APA
Houwen, B. B. S. L., Hazewinkel, Y., Giotis, I., Vleugels, J. L. A., Mostafavi, N. S., van Putten, P., Fockens, P., Dekker, E., & POLAR Study Group (2023). Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: a real-time comparison with screening endoscopists. Endoscopy, 55(08), 756-765. https://doi.org/10.1055/a-2009-3990
Vancouver
Houwen BBSL, Hazewinkel Y, Giotis I, Vleugels JLA, Mostafavi NS, van Putten P, et al. Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: a real-time comparison with screening endoscopists. Endoscopy. 2023;55(08):756-765. doi:10.1055/a-2009-3990
BibTeX
@article{Houwen2023,
author = {Houwen, Britt B S L and Hazewinkel, Yark and Giotis, Ioannis and Vleugels, Jasper L A and Mostafavi, Nahid S and van Putten, Paul and Fockens, Paul and Dekker, Evelien and POLAR Study Group, POLAR Study Group},
title = {Computer-aided diagnosis for optical diagnosis of diminutive colorectal polyps including sessile serrated lesions: a real-time comparison with screening endoscopists},
journal = {Endoscopy},
year = {2023},
volume = {55},
number = {08},
pages = {756--765},
doi = {10.1055/a-2009-3990}
}
EUVIMED