EUVIMEDOpdag EUVIMED
Multizentrische StudieOpen access · CC BY-NC-ND 4.0

A Multicenter Prospective Study on the Safety and Efficacy of the New Low Axial Force Self‐Expandable Metallic Stent With Slim Delivery System for Malignant Colorectal Obstruction

Takeshi Mizumoto, Yuzuru Tamaru, Toshio Kuwai iD, Akihisa Matsuda iD, Shuji Saito, Satoshi Ikeda, Kazuhiro Hiyama iD, Hirofumi Chiba, Yorinobu Sumida, Takaaki Yoshikawa, Chikako Tokoro, Tetsuro Maruyama and 2 more

Digestive Endoscopy · 2026-06 · 38 (6)

DOI: 10.1111/den.70185 ↗

At a glance

Multizentrische Studie in Digestive Endoscopy, published online on 2026-06-02. Written by Takeshi Mizumoto and 13 co-authors. Institution: Department of Endoscopy, NHO Kure Medical Center and Chugoku Cancer Center, Kure, Japan. Major MEDLINE topics: Colorectal Neoplasms, Colorectal Surgical Procedures, Intestinal Obstruction, Self Expandable Metallic Stents. Cited 2 times so far (Crossref); 33 references. The full text is freely available (open access, CC BY-NC-ND 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Objectives

Self‐expandable metallic stents are widely used for malignant colorectal obstruction, and low axial force (AF) stents have been developed to reduce adverse events. The Niti‐S Enteral Colonic Uncovered Stent (MD/BB type) is a new low‐AF stent that maintains a 22 mm outer diameter despite using a 9Fr delivery system. This improves placement performance and reduces adverse events. We aim to evaluate the efficacy and safety of this stent.

Methods

In this prospective, multicenter clinical study, we assess the efficacy and safety of the low‐AF Niti‐S MD/BB stent for colonic stenting. Of the 199 consecutive registered patients who underwent colorectal stenting with the Niti‐S MD/BB stents at 12 centers affiliated with the Japan Colonic Stent Safe Procedure Research Group between February 2019 and March 2023, 193 were included for analysis. The primary endpoint was the clinical success rate. The secondary endpoints included technical success and adverse events.

Results

The technical success rate was 98.4% (190/193), and the clinical success rate was 95.9% (185/193). In all bridge‐to‐surgery cases, elective surgery was successfully performed as planned, and no perforations were observed. In palliative cases, three perforations occurred. Seven patients required surgery in the subsequent year due to adverse events. The 1‐year stent patency rate in PAL cases was 80.6%.

Conclusion

This new low‐AF Niti‐S MD/BB stent demonstrated excellent safety and efficacy, with high technical and clinical success rates and a low incidence of adverse events. Thus, low‐AF stents may be a safe, user‐friendly option for obstructive colorectal cancer.

Subjects

MeSH terms (MEDLINE)

Colorectal NeoplasmsColorectal Surgical ProceduresIntestinal ObstructionSelf Expandable Metallic StentsAgedAged, 80 and overFemaleHumansMaleMiddle AgedJapanProspective StudiesProsthesis DesignTreatment Outcome

Author keywords

bridge‐to‐surgerylow axial forcemalignant colorectal obstructionpalliativeself‐expandable metallic stent

Authors and institutions

  • Department of Endoscopy, NHO Kure Medical Center and Chugoku Cancer Center, Kure, Japan.
  • Gastrointestinal Endoscopy and Medicine, Hiroshima University Hospital, Hiroshima, Japan.
  • Institute for Clinical Research, NHO Kure Medical Center and Chugoku Cancer Center, Kure, Japan.
  • Department of Gastroenterological Surgery, Nippon Medical School, Tokyo, Japan.
  • Division of Surgery, Gastrointestinal Center, Yokohama Shin-Midori General Hospital, Yokohama, Japan.
  • Department of Gastroenterological Surgery, Hiroshima Prefectural Hospital, Hiroshima, Japan.

ORCID profiles: Toshio Kuwai, Akihisa Matsuda, Kazuhiro Hiyama

Cite

APA

Mizumoto, T., Tamaru, Y., Kuwai, T., Matsuda, A., Saito, S., Ikeda, S., Hiyama, K., Chiba, H., Sumida, Y., Yoshikawa, T., Tokoro, C., Maruyama, T., Isayama, H., & Saida, Y. (2026). A Multicenter Prospective Study on the Safety and Efficacy of the New Low Axial Force Self‐Expandable Metallic Stent With Slim Delivery System for Malignant Colorectal Obstruction. Digestive Endoscopy, 38(6). https://doi.org/10.1111/den.70185

Vancouver

Mizumoto T, Tamaru Y, Kuwai T, Matsuda A, Saito S, Ikeda S, et al. A Multicenter Prospective Study on the Safety and Efficacy of the New Low Axial Force Self‐Expandable Metallic Stent With Slim Delivery System for Malignant Colorectal Obstruction. Digestive Endoscopy. 2026;38(6). doi:10.1111/den.70185

BibTeX
@article{Mizumoto2026,
  author = {Mizumoto, Takeshi and Tamaru, Yuzuru and Kuwai, Toshio and Matsuda, Akihisa and Saito, Shuji and Ikeda, Satoshi and Hiyama, Kazuhiro and Chiba, Hirofumi and Sumida, Yorinobu and Yoshikawa, Takaaki and Tokoro, Chikako and Maruyama, Tetsuro and Isayama, Hiroyuki and Saida, Yoshihisa},
  title = {A Multicenter Prospective Study on the Safety and Efficacy of the New Low Axial Force Self‐Expandable Metallic Stent With Slim Delivery System for Malignant Colorectal Obstruction},
  journal = {Digestive Endoscopy},
  year = {2026},
  volume = {38},
  number = {6},
  doi = {10.1111/den.70185}
}
Start for free →