Large Language Model‐Driven Analysis and Report Generation of Endoscopy Videos—A Pilot Study
Digestive Endoscopy · 2026-03 · 38 (3)
DOI: 10.1111/den.70134 ↗At a glance
Journal article in Digestive Endoscopy, published online on 2026-03-10. Written by Davide Massimi and 16 co-authors. Institution: IRCCS Humanitas Research Hospital, Milan, Italy. Major MEDLINE topics: Video Recording, Endoscopy, Digestive System. Cited 5 times so far (Crossref); 6 references. The full text is freely available (open access, CC BY 4.0). Funded by: Fondazione AIRC per la ricerca sul cancro ETS, European Commission (Horizon Europe), Norwegian Research Council.
Abstract (original language)
Multimodal large language models (MLLMs) can automatically analyze clinical video, but evidence from full esophagogastroduodenoscopy (EGD) and the impact of on‐screen computer‐aided detection/diagnosis (CAD) overlays on MLLM behavior remain unclear. We tested whether an MLLM can produce clinically adequate EGD reports and whether a CAD overlay changes performance. We analyzed five complete EGD videos with Gemini 2.5 Pro in paired versions: (1) clean video and (2) the same video with a CAD overlay. Five blinded endoscopists rated report adequacy in three domains. MLLM accuracy for landmarks/lesions was further assessed by two blinded expert endoscopists using the time‐window rule (a model detection counted as correct if it occurred within ±2 s of the expert‐annotated timestamp). In this retrospective pilot study, five archived diagnostic EGD procedures from five patients were available as full‐length videos. Across five raters, MLLM Completeness was judged adequate in 56.0% (14/25 ratings) with Clean‐Video versus 48.0% (12/25 ratings) with Overlay‐Video ( p = 0.500). Visualization was identical (36.0% [9/25 ratings] for both; p = 1.000). Lesions characteristics were identical (16.0% [4/25] for both; p = 1.00). For the Landmark agreement, the overall accuracy of the MLLM with Clean‐Video vs. Overlay‐Video was: 0.55 [95% CI 0.43–0.67] vs. 0.33 [0.23–0.46], p = 0.029; sensitivity 0.53 [0.40–0.66] vs. 0.35 [0.24–0.49], p = 0.122; specificity 0.67 [0.35–0.88] vs. 0.22 [0.06–0.55], p = 0.125. In this pilot study, Gemini 2.5 Pro demonstrated inadequate performance for clinical EGD reporting. These hypothesis‐generating findings suggest substantial optimization and larger‐scale validation are required before deployment.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- IRCCS Humanitas Research Hospital, Milan, Italy.
- Clinical Effectiveness Research Group, University of Oslo, Oslo, Norway.
- Digestive Disease Center, Showa University Northern Yokohama Hospital, Yokohama, Japan.
- Gastroenterology and Digestive Endoscopy Unit, Ospedale dei Castelli, Rome, Italy.
- Division of Gastroenterology, St. Michael's Hospital, University of Toronto, Toronto, Ontario, Canada.
- Department of Gastroenterology and Hepatology, University Hospitals Leuven, TARGID, KU Leuven, Leuven, Belgium.
ORCID profiles: Tommy Rizkala, Kareem Khalaf, Raf Bisschops, Cesare Hassan
Funding
- Fondazione AIRC per la ricerca sul cancro ETS
- European Commission (Horizon Europe)
- Norwegian Research Council
- Flanders
- KU Leuven
- HORIZON EUROPE Framework Programme
- Norges Forskningsråd
- Vlaamse regering
Cite
APA
Massimi, D., Stefano, L. D., Rizkala, T., Spadaccini, M., Mori, Y., Menini, M., Antonelli, G., Khalaf, K., Bisschops, R., von Renteln, D., Sharma, P., Rex, D. K., Bretthauer, M., Castoro, C., LLM Working Group, Repici, A., & Hassan, C. (2026). Large Language Model‐Driven Analysis and Report Generation of Endoscopy Videos—A Pilot Study. Digestive Endoscopy, 38(3). https://doi.org/10.1111/den.70134
Vancouver
Massimi D, Stefano LD, Rizkala T, Spadaccini M, Mori Y, Menini M, et al. Large Language Model‐Driven Analysis and Report Generation of Endoscopy Videos—A Pilot Study. Digestive Endoscopy. 2026;38(3). doi:10.1111/den.70134
BibTeX
@article{Massimi2026,
author = {Massimi, Davide and Stefano, Luca Di and Rizkala, Tommy and Spadaccini, Marco and Mori, Yuichi and Menini, Maddalena and Antonelli, Giulio and Khalaf, Kareem and Bisschops, Raf and von Renteln, Daniel and Sharma, Prateek and Rex, Douglas K and Bretthauer, Michael and Castoro, Carlo and LLM Working Group, LLM Working Group and Repici, Alessandro and Hassan, Cesare},
title = {Large Language Model‐Driven Analysis and Report Generation of Endoscopy Videos—A Pilot Study},
journal = {Digestive Endoscopy},
year = {2026},
volume = {38},
number = {3},
doi = {10.1111/den.70134}
}
EUVIMED