Side‐by‐side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial
Digestive Endoscopy · 2024
DOI: 10.1111/den.14669 ↗At a glance
Randomisierte kontrollierte Studie in Digestive Endoscopy, 2024. Written by Woo Hyun Paik and 9 co-authors. Institution: Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seou…. Major MEDLINE topics: Cholestasis, Self Expandable Metallic Stents, Bile Duct Neoplasms. Cited 20 times so far (Crossref); 28 references. Funded by: Taewoong.
Abstract (original language)
Objectives
We aimed to evaluate the efficacy and safety of metal stents compared with plastic stents when bilateral side‐by‐side stents were deployed for malignant hilar biliary obstruction (MHBO).
Methods
Fifty patients with unresectable advanced MHBO were randomly assigned to the metal stent (MS, n = 25) or plastic stent group (PS, n = 25). Fully covered self‐expandable metal stents with 6 mm diameter and plastic stents with either 7F straight or double pigtail were used for MS and PS groups, respectively. Time to recurrent biliary obstruction (TRBO) was evaluated as the primary outcome.
Results
Both groups had 100% technical success rates; 88% and 76% of clinical success rates were obtained in MS and PS, respectively. Although stent migrations were more frequent in MS than PS (48% vs. 16%, P = 0.02), the mean TRBO was significantly longer in MS (190 days; 95% confidence interval [CI] 121–260 days vs. 96 days; 95% CI 50–141 days, P = 0.02). The placement of plastic stents (hazard ratio 2.42; 95% CI 1.24–4.73; P = 0.01) was the only significant risk factor associated with TRBO in multivariable analysis. The rates of adverse events were similar between the two groups (difference 0%; 95% CI −25% to 25%; P > 0.99).
Conclusions
During bilateral side‐by‐side deployment in MHBO, the use of metal stents appears to be preferable to plastic stents in terms of TRBO, despite a higher frequency of stent migration.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Internal Medicine and Liver Research Institute, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Korea.
- Department of Internal Medicine, School of Medicine, Kyungpook National University, Daegu, Korea.
- Department of Internal Medicine, College of Medicine, Pusan National University, Yangsan, Korea.
- Biomedical Research Institute, Pusan National University Hospital, Busan, Korea.
- Department of Gastroenterology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.
- Department of Gastroenterology, Ajou University School of Medicine, Suwon, Korea.
ORCID profiles: Woo Hyun Paik, Min Jae Yang, Jin Ho Choi, Sang Hyub Lee
Funding
- Taewoong
Cite
APA
Paik, W. H., Jung, M. K., Kim, D. U., Song, T. J., Yang, M. J., Choi, Y. H., Kim, J. S., Lee, M. W., Choi, J. H., & Lee, S. H. (2024). Side‐by‐side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial. Digestive Endoscopy. https://doi.org/10.1111/den.14669
Vancouver
Paik WH, Jung MK, Kim DU, Song TJ, Yang MJ, Choi YH, et al. Side‐by‐side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial. Digestive Endoscopy. 2024. doi:10.1111/den.14669
BibTeX
@article{Paik2024,
author = {Paik, Woo Hyun and Jung, Min Kyu and Kim, Dong Uk and Song, Tae Jun and Yang, Min Jae and Choi, Young Hoon and Kim, Joo Seong and Lee, Min Woo and Choi, Jin Ho and Lee, Sang Hyub},
title = {Side‐by‐side placement of fully covered metal stents versus conventional 7F plastic stents in malignant hilar biliary obstruction: Prospective randomized controlled trial},
journal = {Digestive Endoscopy},
year = {2024},
doi = {10.1111/den.14669}
}
EUVIMED