EUVIMEDScopri EUVIMED
Open access · CC BY-NC 4.0

Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation

Tahira Scott iD, Jasna Aleksova, Carmel Hawley, Mina Khair, Harpreet Kaur, Christopher Schultz, Ryan Gately iD, Mirna Vucak-Dzumhur, James Elhindi, Grahame J Elder

Clinical Transplantation · 2025

DOI: 10.1111/ctr.70177 ↗

At a glance

Journal article in Clinical Transplantation, 2025. Written by Tahira Scott and 9 co-authors. Institution: Department of Nephrology, Level 2, ARTS Building, Princess Alexandra Hospital, Woolloongabba, Brisbane, Queensland, Australia. Major MEDLINE topics: Kidney Transplantation, Absorptiometry, Photon, Bone Density, Pancreas Transplantation. Cited 2 times so far (Crossref); 35 references. The full text is freely available (open access, CC BY-NC 4.0).

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Patients with kidney failure have elevated fracture risk that remains high following kidney transplantation. This study aimed to assess whether dual‐energy x‐ray absorptiometry‐derived advanced hip analysis (AHA) and the trabecular bone score (TBS) improve bone mineral density (BMD)‐based post‐transplant fracture prediction.

Methods

Patients receiving kidney‐only or simultaneous pancreas‐kidney (SPK) transplants underwent immediate post‐transplant dual‐energy x‐ray absorptiometry to provide BMD, the TBS, and AHA parameters; femoral neck, calcar, and shaft cortical thickness (CTh), and femoral neck buckling ratio (BR), an index of structural instability. Patients received treatment to reduce post‐transplant BMD loss, using an established risk algorithm. Hazard ratios were determined using Kaplan–Meier and Cox proportional hazard models.

Results

Of 357 transplant recipients, 289 (83%) received a kidney‐only transplant. There were 83 incident fractures over a median of 4.4 years (IQR: 2.5–5.5). Fracture was associated with type 1 diabetes mellitus ( p < 0.001), former smoking ( p = 0.006), lower 25‐hydroxyvitamin D ( p = 0.003), BMD at total proximal femur and neck of femur ( p < 0.001) and spine ( p = 0.008), lower CTh at the calcar ( p = 0.005) and shaft ( p = 0.023), higher BR ( p = 0.016) and lower TBS ( p = 0.047). Following multivariable adjustment, type 1 diabetes mellitus, 25‐hydroxyvitamin D, smoking, and femoral neck BMD remained significant. Using the BMD‐based risk algorithm, inclusion of the BR improved the model fit.

Conclusion

BMD, the TBS, and AHA parameters are associated with incident fracture in kidney‐only and SPK transplant recipients. Pre‐transplant smoking, lower 25‐hydroxyvitamin D and BMD are potentially modifiable factors that could reduce post‐transplant fracture risk.

Subjects

MeSH terms (MEDLINE)

Kidney TransplantationAbsorptiometry, PhotonBone DensityPancreas TransplantationCancellous BonePostoperative ComplicationsFractures, BoneKidney Failure, ChronicHumansFemaleMaleMiddle AgedFollow-Up StudiesPrognosisRisk FactorsAdultRetrospective StudiesGraft SurvivalGlomerular Filtration Rate

Author keywords

advanced hip analysisbone mineral densityfracturekidney transplantationtrabecular bone scoretype 1 diabetes mellitus

Authors and institutions

  • Department of Nephrology, Level 2, ARTS Building, Princess Alexandra Hospital, Woolloongabba, Brisbane, Queensland, Australia.
  • School of Medicine, University of Queensland, Brisbane, Australia.
  • Department of Medicine, Monash University, Clayton, Victoria, Australia.
  • Department of Endocrinology, Monash Health, Melbourne, Australia.
  • Australasian Kidney Trials Network, University of Queensland, Brisbane, Australia.
  • Translational Research Institute, Brisbane, Australia.

ORCID profiles: Tahira Scott, Ryan Gately

Cite

APA

Scott, T., Aleksova, J., Hawley, C., Khair, M., Kaur, H., Schultz, C., Gately, R., Vucak-Dzumhur, M., Elhindi, J., & Elder, G. J. (2025). Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation. Clinical Transplantation. https://doi.org/10.1111/ctr.70177

Vancouver

Scott T, Aleksova J, Hawley C, Khair M, Kaur H, Schultz C, et al. Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation. Clinical Transplantation. 2025. doi:10.1111/ctr.70177

BibTeX
@article{Scott2025,
  author = {Scott, Tahira and Aleksova, Jasna and Hawley, Carmel and Khair, Mina and Kaur, Harpreet and Schultz, Christopher and Gately, Ryan and Vucak-Dzumhur, Mirna and Elhindi, James and Elder, Grahame J},
  title = {Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation},
  journal = {Clinical Transplantation},
  year = {2025},
  doi = {10.1111/ctr.70177}
}
Start for free →