EUVIMEDScopri EUVIMED
Crossref

The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction

Dorota Nowosielecka iD, Wojciech Jacheć iD, Christoph Starck, Anna Polewczyk iD, Dominika Mościcka iD, Andrzej Kutarski iD

Clinical Physiology and Functional Imaging · 2026-11 · 46 (6)

DOI: 10.1111/cpf.70101 ↗

At a glance

Journal article in Clinical Physiology and Functional Imaging, published online on 2026-10-29. Written by Dorota Nowosielecka and 5 co-authors. Institution: Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland. Major MEDLINE topics: Device Lead Extraction, Heart Septal Defects, Atrial, Postoperative Complications, Pacemaker, Artificial. 44 references. Funded by: Śląski Uniwersytet Medyczny w Katowicach.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Background

Patients with defects of the atrial septum (DAS) undergoing transvenous lead extraction (TLE) may be at increased risk of systemic embolism due to transient right‐to‐left shunting. However, data on the prevalence and clinical relevance of DAS in patients undergoing TLE remain limited.

Methods

This retrospective study included 3637 patients undergoing TLE between 2006 and 2024 with complete preprocedural assessment of the atrial septum and at least 3 years of follow‐up. We evaluated the prevalence of DAS and its association with procedural complexity, major complications, and survival.

Results

DAS was identified in 3.71% of patients. Patent foramen ovale was present in 2.45%, secundum atrial septal defect in 1.15%, and both defects in 0.08%. Most defects were small, with predominant left‐to‐right shunting. Patients with DAS more frequently had lead‐related infective endocarditis and vegetations on transesophageal echocardiography ( p < 0.001). TLE procedures in patients with DAS were more complex, with longer extraction times and more frequent use of advanced extraction tools. Despite higher predicted procedural risk, the incidence of major complications, including stroke, was low. DAS was not associated with increased in‐hospital, 30‐day, 1‐year, or 3‐year mortality.

Conclusions

In this large TLE cohort, DAS was uncommon and associated with greater procedural complexity, but not with a higher incidence of major complications or worse long‐term survival. Clinically apparent systemic embolic events were rare.

Subjects

MeSH terms (MEDLINE)

Device Lead ExtractionHeart Septal Defects, AtrialPostoperative ComplicationsPacemaker, ArtificialDevice RemovalHumansRetrospective StudiesFemaleMaleEchocardiography, TransesophagealMiddle AgedRisk FactorsTreatment OutcomeAgedTime FactorsPrevalenceDefibrillators, Implantable

Author keywords

atrial septal defectlead‐related infective endocarditisparadoxical embolismpatent foramen ovaleprocedural complexitystroketransesophageal echocardiographytransvenous lead extraction

Authors and institutions

  • Department of Cardiac Surgery, The Pope John Paul II Province Hospital, Zamość, Poland.
  • Faculty of Health Sciences, Academy of Zamość, Zamość, Poland.
  • 2nd Department of Cardiology, Faculty of Medical Sciences in Zabrze, Silesian Medical University in Katowice, Zabrze, Poland.
  • Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany.
  • Department of Physiology, Pathophysiology and Clinical Immunology, Collegium Medicum of Jan Kochanowski University, Kielce, Poland.
  • Department of Cardiac Surgery, Swietokrzyskie Cardiology Center, Kielce, Poland.

ORCID profiles: Dorota Nowosielecka, Wojciech Jacheć, Anna Polewczyk, Dominika Mościcka, Andrzej Kutarski

Funding

  • Śląski Uniwersytet Medyczny w Katowicach

Cite

APA

Nowosielecka, D., Jacheć, W., Starck, C., Polewczyk, A., Mościcka, D., & Kutarski, A. (2026). The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction. Clinical Physiology and Functional Imaging, 46(6). https://doi.org/10.1111/cpf.70101

Vancouver

Nowosielecka D, Jacheć W, Starck C, Polewczyk A, Mościcka D, Kutarski A. The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction. Clinical Physiology and Functional Imaging. 2026;46(6). doi:10.1111/cpf.70101

BibTeX
@article{Nowosielecka2026,
  author = {Nowosielecka, Dorota and Jacheć, Wojciech and Starck, Christoph and Polewczyk, Anna and Mościcka, Dominika and Kutarski, Andrzej},
  title = {The impact of defects of the atrial septum on procedural complexity, complications, and outcomes of transvenous lead extraction},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  volume = {46},
  number = {6},
  doi = {10.1111/cpf.70101}
}
Start for free →