The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model
Clinical Physiology and Functional Imaging · 2026
DOI: 10.1111/cpf.70099 ↗At a glance
Vergleichsstudie in Clinical Physiology and Functional Imaging, 2026. Written by Henrik Bjursten and 4 co-authors. Institution: Department of Cardiothoracic Surgery, Lund University, Skåne University Hospital, Lund, Sweden. Major MEDLINE topics: Mitral Valve, Heart Ventricles, Papillary Muscles, Sutures. 21 references. The full text is freely available (open access, CC BY 4.0). Funded by: Hjärt-Lungfonden, Familjen Erling-Perssons Stiftelse, Lund University Medical Faculty Foundation.
Abstract (original language)
Objective
Surgical mitral valve repair, including anchoring in different parts of the mitral apparatus, is the standard of care for severe mitral regurgitation. Various percutaneous approaches have been developed and are currently under development, but are struggling with durable results. This study investigates the durability of different anatomic anchoring points and anchoring types in the left ventricle. Material and Methods Anchoring was tested with PTFE sutures or a 5 mm helix at three locations: the head of the papillary muscle, the lateral wall of the ventricle, and the apex of the ventricle. An accelerated life test was performed with 300 cycles at 3 N for each anchoring. Durability was assessed by measuring compliance (strain in mm until 3 N is reached), migration (change in strain from the first to the last cycle), and the occurrence of dehiscence.
Results
The lowest numerical strain/compliance in the first cycle was observed at the head of the papillary muscle anchoring (both surgical and helix). Migration of strain limits over 300 cycles was seen for all locations. The lowest migration was numerically for helix in the papillary muscle.
Conclusion
PTFE in the head of the papillary muscle is standard practice in mitral valve repair and was used as a reference in the present study. The anchoring that yielded the most similar results was a helix in the papillary muscle, whereas other anchoring points showed greater compliance and/or migration.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Cardiothoracic Surgery, Lund University, Skåne University Hospital, Lund, Sweden.
- Department of Cardiothoracic Surgery, Cleveland Clinic, Cleveland, Ohio, USA.
- Department of Clinical Sciences Lund, Cardiology, Lund University, Skåne University Hospital, Lund, Sweden.
- Department of Medical Imaging and Physiology, Skåne University Hospital, Malmö, Sweden.
- Department of Translational Medicine, Lund University, Lund, Sweden.
ORCID profiles: Magnus Dencker
Funding
- Hjärt-Lungfonden
- Familjen Erling-Perssons Stiftelse
- Lund University Medical Faculty Foundation
Cite
APA
Bjursten, H., Wierup, P., Koul, S., Götberg, M., & Dencker, M. (2026). The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70099
Vancouver
Bjursten H, Wierup P, Koul S, Götberg M, Dencker M. The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model. Clinical Physiology and Functional Imaging. 2026. doi:10.1111/cpf.70099
BibTeX
@article{Bjursten2026,
author = {Bjursten, Henrik and Wierup, Per and Koul, Sasha and Götberg, Matthias and Dencker, Magnus},
title = {The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
doi = {10.1111/cpf.70099}
}
EUVIMED