EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model

Henrik Bjursten, Per Wierup, Sasha Koul, Matthias Götberg, Magnus Dencker iD

Clinical Physiology and Functional Imaging · 2026

DOI: 10.1111/cpf.70099 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, 2026. Verfasst von Henrik Bjursten und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Lund University, Skåne University Hospital, Lund, Sweden. Hauptthemen laut MEDLINE: Mitral Valve, Heart Ventricles, Papillary Muscles, Sutures. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hjärt-Lungfonden, Familjen Erling-Perssons Stiftelse, Lund University Medical Faculty Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

Surgical mitral valve repair, including anchoring in different parts of the mitral apparatus, is the standard of care for severe mitral regurgitation. Various percutaneous approaches have been developed and are currently under development, but are struggling with durable results. This study investigates the durability of different anatomic anchoring points and anchoring types in the left ventricle. Material and Methods Anchoring was tested with PTFE sutures or a 5 mm helix at three locations: the head of the papillary muscle, the lateral wall of the ventricle, and the apex of the ventricle. An accelerated life test was performed with 300 cycles at 3 N for each anchoring. Durability was assessed by measuring compliance (strain in mm until 3 N is reached), migration (change in strain from the first to the last cycle), and the occurrence of dehiscence.

Results

The lowest numerical strain/compliance in the first cycle was observed at the head of the papillary muscle anchoring (both surgical and helix). Migration of strain limits over 300 cycles was seen for all locations. The lowest migration was numerically for helix in the papillary muscle.

Conclusion

PTFE in the head of the papillary muscle is standard practice in mitral valve repair and was used as a reference in the present study. The anchoring that yielded the most similar results was a helix in the papillary muscle, whereas other anchoring points showed greater compliance and/or migration.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Mitral ValveHeart VentriclesPapillary MusclesSuturesSuture TechniquesMitral Valve InsufficiencyHeart Valve Prosthesis ImplantationAnimalsPolytetrafluoroethyleneMaterials TestingStress, MechanicalTime FactorsBiomechanical PhenomenaModels, AnimalSus scrofaSwineProsthesis Design

Stichwörter der Autor:innen

Mitral valveanchoringdurabilityex vivostrain

Substanzen

Polytetrafluoroethylene

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Lund University, Skåne University Hospital, Lund, Sweden.
  • Department of Cardiothoracic Surgery, Cleveland Clinic, Cleveland, Ohio, USA.
  • Department of Clinical Sciences Lund, Cardiology, Lund University, Skåne University Hospital, Lund, Sweden.
  • Department of Medical Imaging and Physiology, Skåne University Hospital, Malmö, Sweden.
  • Department of Translational Medicine, Lund University, Lund, Sweden.

ORCID-Profile: Magnus Dencker

Förderung

  • Hjärt-Lungfonden
  • Familjen Erling-Perssons Stiftelse
  • Lund University Medical Faculty Foundation

Zitieren

APA

Bjursten, H., Wierup, P., Koul, S., Götberg, M., & Dencker, M. (2026). The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.70099

Vancouver

Bjursten H, Wierup P, Koul S, Götberg M, Dencker M. The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model. Clinical Physiology and Functional Imaging. 2026. doi:10.1111/cpf.70099

BibTeX
@article{Bjursten2026,
  author = {Bjursten, Henrik and Wierup, Per and Koul, Sasha and Götberg, Matthias and Dencker, Magnus},
  title = {The durability of different anchoring points and anchoring types in the left ventricle in an ex vivo porcine model},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  doi = {10.1111/cpf.70099}
}
Kostenlos starten →