Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors
Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)
DOI: 10.1111/cpf.70078 ↗At a glance
Vergleichsstudie in Clinical Physiology and Functional Imaging, published online on 2026-07-06. Written by Kaat Verbeelen and 5 co-authors. Institution: Department of Rehabilitation Sciences and Physiotherapy, MOVANT Research Group, University of Antwerp, Antwerp, Belgium. Major MEDLINE topics: Breast Neoplasms, Elasticity Imaging Techniques, Cancer Survivors, Pectoralis Muscles. 86 references. Funded by: Fonds Wetenschappelijk Onderzoek.
Abstract (original language)
Introduction
Breast cancer treatments can alter local soft‐tissue structure and mechanics, contributing to upper‐limb dysfunction. Ultrasound (US) and shear‐wave elastography (SWE) assess tissue stiffness, while deformation‐based tools (Elastimeter, MyotonPRO) provide accessible alternatives, though their reliability and agreement are unclear. This study evaluated (1) intra‐ and interrater reliability of US, SWE, MyotonPRO and Elastimeter for measuring tissue thickness, composition and stiffness, and (2) correlations between SWE and deformation‐based tools.
Methods
Thirty breast cancer survivors were assessed at four pectoralis major regions on affected and non‐affected sides. Skin, fat and muscle thickness, muscle composition, and stiffness were measured using US and SWE (MACH 30), with additional stiffness measures from MyotonPRO and Elastimeter. Three assessors performed repeated sessions. Reliability was analysed using ICC(3,1), SEM, %SEM, and SRD. Correlations were assessed with Spearman's coefficients.
Results
Muscle thickness and composition showed weak–moderate reliability (ICC 0.237–0.766). SWE stiffness also showed weak–moderate reliability (ICC −0.032–0.539) with large measurement error. Deformation‐based tools showed similar reliability (ICC 0.246–0.737), with greatest variability for MyotonPRO. No significant correlations were found between SWE and deformation‐based measures.
Conclusion
US measurements of skin and fat thickness were most reliable. Deeper‐tissue assessments showed substantial variability, likely due to anatomical complexity, probe stability and device limitations. Stiffness tools were not interchangeable.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Rehabilitation Sciences and Physiotherapy, MOVANT Research Group, University of Antwerp, Antwerp, Belgium.
- Department of Rehabilitation Sciences, KU Leuven, University of Leuven, Leuven, Belgium.
- CarEdOn Research Group, Belgium.
- Pain in Motion International Research Consortium, Antwerp, Belgium.
- Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
- Laboratory of Experimental Radiotherapy, Department of Oncology, University of Leuven, Leuven, Belgium.
ORCID profiles: Kaat Verbeelen, Kaat Van Aperen, Nele Devoogdt
Funding
- Fonds Wetenschappelijk Onderzoek
Cite
APA
Verbeelen, K., Gursen, C., Aperen, K. V., Mertens, M. G., Devoogdt, N., & Groef, A. (2026). Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70078
Vancouver
Verbeelen K, Gursen C, Aperen KV, Mertens MG, Devoogdt N, Groef A. Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70078
BibTeX
@article{Verbeelen2026,
author = {Verbeelen, Kaat and Gursen, Ceren and Aperen, Kaat Van and Mertens, Michel Gcam and Devoogdt, Nele and Groef, An De},
title = {Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
volume = {46},
number = {4},
doi = {10.1111/cpf.70078}
}
EUVIMED