EUVIMEDEUVIMED entdecken
Vergleichsstudie

Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors

Kaat Verbeelen iD, Ceren Gursen, Kaat Van Aperen iD, Michel Gcam Mertens, Nele Devoogdt iD, An De Groef

Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)

DOI: 10.1111/cpf.70078 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 06.07.2026. Verfasst von Kaat Verbeelen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Rehabilitation Sciences and Physiotherapy, MOVANT Research Group, University of Antwerp, Antwerp, Belgium. Hauptthemen laut MEDLINE: Breast Neoplasms, Elasticity Imaging Techniques, Cancer Survivors, Pectoralis Muscles. Die Arbeit nennt 86 Literaturangaben. Gefördert von: Fonds Wetenschappelijk Onderzoek.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Breast cancer treatments can alter local soft‐tissue structure and mechanics, contributing to upper‐limb dysfunction. Ultrasound (US) and shear‐wave elastography (SWE) assess tissue stiffness, while deformation‐based tools (Elastimeter, MyotonPRO) provide accessible alternatives, though their reliability and agreement are unclear. This study evaluated (1) intra‐ and interrater reliability of US, SWE, MyotonPRO and Elastimeter for measuring tissue thickness, composition and stiffness, and (2) correlations between SWE and deformation‐based tools.

Methods

Thirty breast cancer survivors were assessed at four pectoralis major regions on affected and non‐affected sides. Skin, fat and muscle thickness, muscle composition, and stiffness were measured using US and SWE (MACH 30), with additional stiffness measures from MyotonPRO and Elastimeter. Three assessors performed repeated sessions. Reliability was analysed using ICC(3,1), SEM, %SEM, and SRD. Correlations were assessed with Spearman's coefficients.

Results

Muscle thickness and composition showed weak–moderate reliability (ICC 0.237–0.766). SWE stiffness also showed weak–moderate reliability (ICC −0.032–0.539) with large measurement error. Deformation‐based tools showed similar reliability (ICC 0.246–0.737), with greatest variability for MyotonPRO. No significant correlations were found between SWE and deformation‐based measures.

Conclusion

US measurements of skin and fat thickness were most reliable. Deeper‐tissue assessments showed substantial variability, likely due to anatomical complexity, probe stability and device limitations. Stiffness tools were not interchangeable.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Breast NeoplasmsElasticity Imaging TechniquesCancer SurvivorsPectoralis MusclesBreast Cancer LymphedemaHumansFemaleReproducibility of ResultsObserver VariationMiddle AgedPredictive Value of TestsAgedAdultAdipose Tissue

Stichwörter der Autor:innen

MyotonPROelastimetershear wave elastographytissue compositiontissue stiffnesstissue thicknessultrasound imaging

Autor:innen und Institutionen

  • Department of Rehabilitation Sciences and Physiotherapy, MOVANT Research Group, University of Antwerp, Antwerp, Belgium.
  • Department of Rehabilitation Sciences, KU Leuven, University of Leuven, Leuven, Belgium.
  • CarEdOn Research Group, Belgium.
  • Pain in Motion International Research Consortium, Antwerp, Belgium.
  • Faculty of Physical Therapy and Rehabilitation, Hacettepe University, Ankara, Turkey.
  • Laboratory of Experimental Radiotherapy, Department of Oncology, University of Leuven, Leuven, Belgium.

ORCID-Profile: Kaat Verbeelen, Kaat Van Aperen, Nele Devoogdt

Förderung

  • Fonds Wetenschappelijk Onderzoek

Zitieren

APA

Verbeelen, K., Gursen, C., Aperen, K. V., Mertens, M. G., Devoogdt, N., & Groef, A. (2026). Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70078

Vancouver

Verbeelen K, Gursen C, Aperen KV, Mertens MG, Devoogdt N, Groef A. Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70078

BibTeX
@article{Verbeelen2026,
  author = {Verbeelen, Kaat and Gursen, Ceren and Aperen, Kaat Van and Mertens, Michel Gcam and Devoogdt, Nele and Groef, An De},
  title = {Intra‐ and interrater reliability and inter‐method correlations of soft tissue property measurements in the pectoral region of breast cancer survivors},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  volume = {46},
  number = {4},
  doi = {10.1111/cpf.70078}
}
Kostenlos starten →