EUVIMEDOpdag EUVIMED
Beobachtungsstudie

Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults

Yoshio Tatsuoka, Megan Longley, Dean MacCarter, Zyad J Carr iD

Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)

DOI: 10.1111/cpf.70076 ↗

At a glance

Beobachtungsstudie in Clinical Physiology and Functional Imaging, published online on 2026-06-24. Written by Yoshio Tatsuoka and 3 co-authors. Institution: Department of Anesthesiology, TidalHealth Peninsula Regional, Salisbury, Maryland, USA. Major MEDLINE topics: Exercise Test, Lung, Pulmonary Artery, Pulmonary Gas Exchange. 32 references. Funded by: Shape Medical Systems, Inc (Minnesota, USA).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Gas‐exchange derived pulmonary capacitance (GXCAP) is a non‐invasive index of pulmonary arterial capacitance obtainable from submaximal cardiopulmonary exercise testing (CPET), but reference intervals in older adults, a key target population, are lacking.

Methods

A secondary analysis of an open‐label clinical device trial, including 207 adults ≥ 60 years undergoing elective non‐cardiac surgery was performed. Submaximal CPET with the Shape II system provided peak GXCAP, GXCAP–time slope, and GXCAP–VO 2 slope. Sex‐specific empirical 95% reference intervals (2.5th–97.5th percentiles) and indirect reference intervals were calculated using the refineR algorithm, which models the latent healthy subpopulation within routine data. Associations with age and sex were examined using correlation and group comparisons.

Results

The analytic cohort comprised 207 nonsmoking participants (119 males, 88 females). Males demonstrated higher peak GXCAP and steeper GXCAP–time and GXCAP–VO 2 slopes than females. Age was modestly and inversely associated with peak GXCAP and GXCAP–time slope. Empirical reference intervals were wide and right‐skewed, whereas refineR produced narrower, physiologically plausible intervals, for example, peak GXCAP 144.9–810.0 mL.mmHg (overall), with higher upper limits in males.

Conclusions

In older adults undergoing preoperative evaluation, GXCAP metrics show clear sex differences. Indirect, refineR‐based, reference intervals provide stable, clinically interpretable ranges that may enhance the use of GXCAP for noninvasively assessing pulmonary arterial capacitance in submaximal CPET. GXCAP derivatives (GXCAP–time slope and GXCAP–VO 2 slope were introduced and may offer distinct advantages in submaximal cardiopulmonary exercise testing. Clinical Trial Registration NCT05743673, Principal Investigator: Zyad J. Carr, M.D.

Subjects

MeSH terms (MEDLINE)

Exercise TestLungPulmonary ArteryPulmonary Gas ExchangeVascular CapacitanceAgedFemaleHumansMaleMiddle AgedAge FactorsOxygen ConsumptionPredictive Value of TestsReference ValuesReproducibility of ResultsSex Factors

Author keywords

GXCAPcardiopulmonary exercise testinggas exchange derived pulmonary capacitancepulmonary arterial capacitancereference intervalssubmaximal cardiopulmonary exercise testing

Authors and institutions

  • Department of Anesthesiology, TidalHealth Peninsula Regional, Salisbury, Maryland, USA.
  • Department of Anesthesiology, School of Medicine, Yale University, New Haven, Connecticut, USA.
  • Shape Medical Systems, Inc., White Bear Lake, Minnesota, USA.

ORCID profiles: Zyad J Carr

Funding

  • Shape Medical Systems, Inc (Minnesota, USA)

Cite

APA

Tatsuoka, Y., Longley, M., MacCarter, D., & Carr, Z. J. (2026). Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70076

Vancouver

Tatsuoka Y, Longley M, MacCarter D, Carr ZJ. Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70076

BibTeX
@article{Tatsuoka2026,
  author = {Tatsuoka, Yoshio and Longley, Megan and MacCarter, Dean and Carr, Zyad J},
  title = {Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  volume = {46},
  number = {4},
  doi = {10.1111/cpf.70076}
}
Start for free →