EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults

Yoshio Tatsuoka, Megan Longley, Dean MacCarter, Zyad J Carr iD

Clinical Physiology and Functional Imaging · 2026-07 · 46 (4)

DOI: 10.1111/cpf.70076 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 24.06.2026. Verfasst von Yoshio Tatsuoka und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, TidalHealth Peninsula Regional, Salisbury, Maryland, USA. Hauptthemen laut MEDLINE: Exercise Test, Lung, Pulmonary Artery, Pulmonary Gas Exchange. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Shape Medical Systems, Inc (Minnesota, USA).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Gas‐exchange derived pulmonary capacitance (GXCAP) is a non‐invasive index of pulmonary arterial capacitance obtainable from submaximal cardiopulmonary exercise testing (CPET), but reference intervals in older adults, a key target population, are lacking.

Methods

A secondary analysis of an open‐label clinical device trial, including 207 adults ≥ 60 years undergoing elective non‐cardiac surgery was performed. Submaximal CPET with the Shape II system provided peak GXCAP, GXCAP–time slope, and GXCAP–VO 2 slope. Sex‐specific empirical 95% reference intervals (2.5th–97.5th percentiles) and indirect reference intervals were calculated using the refineR algorithm, which models the latent healthy subpopulation within routine data. Associations with age and sex were examined using correlation and group comparisons.

Results

The analytic cohort comprised 207 nonsmoking participants (119 males, 88 females). Males demonstrated higher peak GXCAP and steeper GXCAP–time and GXCAP–VO 2 slopes than females. Age was modestly and inversely associated with peak GXCAP and GXCAP–time slope. Empirical reference intervals were wide and right‐skewed, whereas refineR produced narrower, physiologically plausible intervals, for example, peak GXCAP 144.9–810.0 mL.mmHg (overall), with higher upper limits in males.

Conclusions

In older adults undergoing preoperative evaluation, GXCAP metrics show clear sex differences. Indirect, refineR‐based, reference intervals provide stable, clinically interpretable ranges that may enhance the use of GXCAP for noninvasively assessing pulmonary arterial capacitance in submaximal CPET. GXCAP derivatives (GXCAP–time slope and GXCAP–VO 2 slope were introduced and may offer distinct advantages in submaximal cardiopulmonary exercise testing. Clinical Trial Registration NCT05743673, Principal Investigator: Zyad J. Carr, M.D.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Exercise TestLungPulmonary ArteryPulmonary Gas ExchangeVascular CapacitanceAgedFemaleHumansMaleMiddle AgedAge FactorsOxygen ConsumptionPredictive Value of TestsReference ValuesReproducibility of ResultsSex Factors

Stichwörter der Autor:innen

GXCAPcardiopulmonary exercise testinggas exchange derived pulmonary capacitancepulmonary arterial capacitancereference intervalssubmaximal cardiopulmonary exercise testing

Autor:innen und Institutionen

  • Department of Anesthesiology, TidalHealth Peninsula Regional, Salisbury, Maryland, USA.
  • Department of Anesthesiology, School of Medicine, Yale University, New Haven, Connecticut, USA.
  • Shape Medical Systems, Inc., White Bear Lake, Minnesota, USA.

ORCID-Profile: Zyad J Carr

Förderung

  • Shape Medical Systems, Inc (Minnesota, USA)

Zitieren

APA

Tatsuoka, Y., Longley, M., MacCarter, D., & Carr, Z. J. (2026). Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults. Clinical Physiology and Functional Imaging, 46(4). https://doi.org/10.1111/cpf.70076

Vancouver

Tatsuoka Y, Longley M, MacCarter D, Carr ZJ. Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults. Clinical Physiology and Functional Imaging. 2026;46(4). doi:10.1111/cpf.70076

BibTeX
@article{Tatsuoka2026,
  author = {Tatsuoka, Yoshio and Longley, Megan and MacCarter, Dean and Carr, Zyad J},
  title = {Defining reference intervals for submaximal cardiopulmonary exercise testing‐derived gas‐exchange derived pulmonary capacitance in older adults},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2026},
  volume = {46},
  number = {4},
  doi = {10.1111/cpf.70076}
}
Kostenlos starten →