Performance of exercise transcutaneous oximetry versus imaging at the buttock, thigh and calf level for the diagnosis of peripheral artery disease
Clinical Physiology and Functional Imaging · 2026-05 · 46 (3)
DOI: 10.1111/cpf.70068 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Clinical Physiology and Functional Imaging, online erschienen am 18.05.2026. Verfasst von Mariève Houle und 5 weiteren Autor:innen. Beteiligte Einrichtung: Université d'Angers, Inserm, CNRS, MITOVASC, Equipe CarMe, SFR ICAT, Angers, France. Hauptthemen laut MEDLINE: Blood Gas Monitoring, Transcutaneous, Peripheral Arterial Disease, Thigh, Intermittent Claudication. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Exercise transcutaneous oximetry (Ex‐TcPO 2 ), through the minimal value of the “decrease from rest of oxygen pressure” (DROPmin), identifies ischemia during exercise in patients with PAD. However, its diagnostic performance at the thigh level compared to imaging modalities, has not been evaluated. The objective of this retrospective study was to perform an external validation of Ex‐TcPO₂ results at the buttock and calf, a first validation of Ex‐TcPO₂ at the thigh level and to determine the respective diagnostic performance of the DROPmin and DROPend (the DROP at the time of exercise cessation).
Methods
We studied 192 patients complaining of intermittent claudication. We retrieved DROPmin and DROPend values from Ex‐TcPO 2 testing and the presence/absence of an ipsilateral significant stenosis ( ≥ 70%) at imaging.
Results
The performance of Ex‐TcPO₂ using DROPmin values at the buttock, thigh and calf levels were respectively fair (AUC = 0.70; 95% CI: 0.64–0.76), fair (AUC = 0.77; 95% CI: 0.72–0.83) and excellent (AUC = 0.93; 95% CI: 0.90–0.96). When using DROPend, the performance of Ex‐TcPO 2 was no more significant. Discussion/Conclusion This study showed that Ex‐TcPO₂ has a fair to excellent accuracy for detecting the presence of at least one artery stenosis ≥70% in the lower limb according to buttock, thigh and calf area in highly selected patients. This study also highlights the importance of using the minimal value of DROPmin rather than the DROPend.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Université d'Angers, Inserm, CNRS, MITOVASC, Equipe CarMe, SFR ICAT, Angers, France.
- Service of Sports Medicine, Angers University Hospital, Angers, France.
- Service of Vascular Medicine, Angers University Hospital, Angers, France.
- School of Electronics (ESEO), Angers, France.
- UMR CNRS, Le Mans, France.
ORCID-Profile: Mariève Houle, Pierre Abraham
Zitieren
APA
Houle, M., Lecoq, S., Feuilloy, M., Hersant, J., Henni, S., & Abraham, P. (2026). Performance of exercise transcutaneous oximetry versus imaging at the buttock, thigh and calf level for the diagnosis of peripheral artery disease. Clinical Physiology and Functional Imaging, 46(3). https://doi.org/10.1111/cpf.70068
Vancouver
Houle M, Lecoq S, Feuilloy M, Hersant J, Henni S, Abraham P. Performance of exercise transcutaneous oximetry versus imaging at the buttock, thigh and calf level for the diagnosis of peripheral artery disease. Clinical Physiology and Functional Imaging. 2026;46(3). doi:10.1111/cpf.70068
BibTeX
@article{Houle2026,
author = {Houle, Mariève and Lecoq, Simon and Feuilloy, Mathieu and Hersant, Jeanne and Henni, Samir and Abraham, Pierre},
title = {Performance of exercise transcutaneous oximetry versus imaging at the buttock, thigh and calf level for the diagnosis of peripheral artery disease},
journal = {Clinical Physiology and Functional Imaging},
year = {2026},
volume = {46},
number = {3},
doi = {10.1111/cpf.70068}
}
EUVIMED