EUVIMEDAtrasti EUVIMED
Open access · CC BY-NC 4.0

Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery

Søren Gam, Anders K Petz, Lukas R Bjerre, Jeppe Bøgild, Anders B Nielsen, Rikke N Sørensen, Mikkel I Kolind, Bibi Gram, Stinus Hansen, Per Aagaard

Clinical Physiology and Functional Imaging · 2024

DOI: 10.1111/cpf.12876 ↗

At a glance

Journal article in Clinical Physiology and Functional Imaging, 2024. Written by Søren Gam and 9 co-authors. Institution: Department of Diabetes and Endocrinology, University Hospital of Southern Denmark, Esbjerg, Denmark. Major MEDLINE topics: Muscle Strength, Bariatric Surgery, Muscle Strength Dynamometer, Torque. Cited 4 times so far (Crossref); 57 references. The full text is freely available (open access, CC BY-NC 4.0). Funded by: The Strategic Clinical Research Fund at the Region of Southern Denmark, Department of Regional Health Research at University of Southern Denmark, Steno Diabetes Center Odense, Denmark.

SantraukaSubjectsBibliografiniai duomenysCiteRelated studies

Abstract (original language)

Background

The aim of this study was to examine the test−retest reliability in lower limb muscle strength and rate of torque development (RTD) using isokinetic dynamometry in adults with obesity, with a body mass index (BMI) ≥ 35 kg/m 2 .

Method

Thirty‐two adults with a BMI of 43.8 ± 6.6 kg/m 2 eligible for bariatric surgery were enroled in the study. Isokinetic and isometric knee extensor (KE) and flexor (KF) strength were assessed in an isokinetic dynamometer (Biodex 4) during three test sessions separated by 3−7 days.

Results

There were no statistical differences in peak KE and KF torque for any test modalities between sessions. Intraclass correlation (ICC) was 0.91−0.94 between sessions 1 and 2 and 0.94−0.97 between sessions 2 and 3. Standard error of measurement (SEM%) and coefficient of variation (CV) ranged across test sessions from 4.3% to 7.3%. KE RTD showed high test−retest reliability following familiarization, with ICC, CV and SEM% values ranging from 0.84 to 0.90, 13.3%−20.3% and 14.6%−24.9%, respectively.

Conclusion

Maximal lower limb muscle strength measured by isokinetic dynamometry showed excellent test−retest reliability manifested by small measurement errors and low CV. Reliability was slightly improved by including a familiarization session. KE RTD but not KF RTD demonstrated high test−retest reliability following familiarization. The present data indicate that isokinetic dynamometry can be used to detect even small changes in lower limb muscle strength in adults with obesity.

Subjects

MeSH terms (MEDLINE)

Muscle StrengthBariatric SurgeryMuscle Strength DynamometerTorqueObesityMuscle, SkeletalLower ExtremityPredictive Value of TestsHumansReproducibility of ResultsMaleFemaleAdultMiddle AgedBody Mass IndexIsometric ContractionTime Factors

Author keywords

bariatric surgeryisokinetic dynamometrymuscle strengthobesityrate of force development (RFD)

Authors and institutions

  • Department of Diabetes and Endocrinology, University Hospital of Southern Denmark, Esbjerg, Denmark.
  • Department of Regional Health Research, University of Southern Denmark, Odense, Denmark.
  • Steno Diabetes Center Odense, Odense, Denmark.
  • Department of Sports Science and Clinical Biomechanics, University of Southern Denmark, Odense, Denmark.
  • Research unit of Endocrinology: Bariatrics and Diabetes, University Hospital of Southern Denmark, Esbjerg, Denmark.

Funding

  • The Strategic Clinical Research Fund at the Region of Southern Denmark
  • Department of Regional Health Research at University of Southern Denmark
  • Steno Diabetes Center Odense, Denmark
  • A. P. Møller Foundation

Cite

APA

Gam, S., Petz, A. K., Bjerre, L. R., Bøgild, J., Nielsen, A. B., Sørensen, R. N., Kolind, M. I., Gram, B., Hansen, S., & Aagaard, P. (2024). Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12876

Vancouver

Gam S, Petz AK, Bjerre LR, Bøgild J, Nielsen AB, Sørensen RN, et al. Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery. Clinical Physiology and Functional Imaging. 2024. doi:10.1111/cpf.12876

BibTeX
@article{Gam2024,
  author = {Gam, Søren and Petz, Anders K and Bjerre, Lukas R and Bøgild, Jeppe and Nielsen, Anders B and Sørensen, Rikke N and Kolind, Mikkel I and Gram, Bibi and Hansen, Stinus and Aagaard, Per},
  title = {Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2024},
  doi = {10.1111/cpf.12876}
}
Start for free →