EUVIMEDOpdag EUVIMED
Randomisierte kontrollierte StudieOpen access · CC BY 4.0

Effect of cryothermic and radiofrequency Cox‐Maze IV ablation on atrial size and function assessed by 2D and 3D echocardiography, a randomized trial. To freeze or to burn

Gabriella Boano, Farkas Vánky, Meriam Åström Aneq

Clinical Physiology and Functional Imaging · 2023

DOI: 10.1111/cpf.12841 ↗

At a glance

Randomisierte kontrollierte Studie in Clinical Physiology and Functional Imaging, 2023. Written by Gabriella Boano and 2 co-authors. Institution: Department of Thoracic and Vascular Surgery in Östergötland, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping,…. Major MEDLINE topics: Atrial Fibrillation, Atrial Remodeling, Catheter Ablation, Echocardiography, Three-Dimensional. Cited 4 times so far (Crossref); 30 references. The full text is freely available (open access, CC BY 4.0). Funded by: ALF Grant Region Ostergotland.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Atrial linear scars in Cox‐Maze IV procedures are achieved using Cryothermy (Cryo) or radiofrequency (RF) techniques. The subsequent postoperative left atrial (LA) reverse remodelling is unclear. We used 2‐ and 3‐dimensional echocardiography (2‐3DE) to compare the impact of Cryo and RF procedures on LA size and function 1 year after Cox‐maze IV ablation concomitant with Mitral valve (MV) surgery.

Methods

Seventy‐two patients with MV disease and AF were randomized to Cryo ( n = 35) or RF ( n = 37) ablation. Another 33 patients were enroled without ablation (NoMaze). All patients underwent an echocardiogram the day before and 1 year after surgery. The LA function was assessed on 2D strain by speckle tracking and 3DE.

Results

Forty‐two ablated patients recovered sinus rhythm (SR) 1 year after surgery. They had comparable left and right systolic ventricular function, LA volume index (LAVI), and 2D reservoir strain before surgery. At follow‐up, the 3DE extracted reservoir and booster function were higher after RF (37 ± 10% vs. 26 ± 6%; p < 0.001) than Cryo ablation (18 ± 9 vs. 7 ± 4%; p < 0.001), while passive conduit function was comparable between groups (24 ± 11 vs. 20 ± 8%; p = 0.17). The extent of LAVI reduction depended on the duration of AF preoperatively.

Conclusions

SR restoration after MV surgery and maze results in LA size reduction irrespective of the energy source used. Compared to RF, the extension of ablation area produced by Cryo implies a structural LA remodelling affecting LA systolic function.

Subjects

MeSH terms (MEDLINE)

Atrial FibrillationAtrial RemodelingCatheter AblationEchocardiography, Three-DimensionalHumansHeart AtriaMaze ProcedureTreatment Outcome

Author keywords

3D volumesatrial fibrillationatrial strainleft atriummitral valve surgerysurgical ablation

Authors and institutions

  • Department of Thoracic and Vascular Surgery in Östergötland, and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.
  • Department of Clinical Physiology in Linköping, Department of Health, Medicine and Caring Sciences Linköping University, Linköping, Sweden.

Funding

  • ALF Grant Region Ostergotland

Cite

APA

Boano, G., Vánky, F., & Åström Aneq, M. (2023). Effect of cryothermic and radiofrequency Cox‐Maze IV ablation on atrial size and function assessed by 2D and 3D echocardiography, a randomized trial. To freeze or to burn. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/cpf.12841

Vancouver

Boano G, Vánky F, Åström Aneq M. Effect of cryothermic and radiofrequency Cox‐Maze IV ablation on atrial size and function assessed by 2D and 3D echocardiography, a randomized trial. To freeze or to burn. Clinical Physiology and Functional Imaging. 2023. doi:10.1111/cpf.12841

BibTeX
@article{Boano2023,
  author = {Boano, Gabriella and Vánky, Farkas and Åström Aneq, Meriam},
  title = {Effect of cryothermic and radiofrequency Cox‐Maze IV ablation on atrial size and function assessed by 2D and 3D echocardiography, a randomized trial. To freeze or to burn},
  journal = {Clinical Physiology and Functional Imaging},
  year = {2023},
  doi = {10.1111/cpf.12841}
}
Start for free →