A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis
Colorectal Disease · 2024-04 · 26 (4) · 754-759
DOI: 10.1111/codi.16880 ↗At a glance
Video/Audio in Colorectal Disease, published online on 2024-03-05. Written by Shinichiro Mori and 10 co-authors. Institution: Department of Digestive Surgery, Kagoshima City Hospital, Kagoshima, Japan. Major MEDLINE topics: Colectomy, Anastomosis, Surgical, Robotic Surgical Procedures, Absorbable Implants. Cited 3 times so far (Crossref); 15 references.
Abstract (original language)
Aim
Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA.
Method
The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material.
Results
This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228–459 min), 12 min (range 11–17 min), 10 mL (range 0–110 mL), and 10 days (range 8–15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications.
Conclusion
The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Department of Digestive Surgery, Kagoshima City Hospital, Kagoshima, Japan.
- Department of Digestive Surgery, Graduate School of Medicine, Kagoshima University, Kagoshima, Japan.
Cite
APA
Mori, S., Kita, Y., Baba, K., Tanabe, K., Wada, M., Yoshino, S., Nishida, N., Iino, S., Setoyama, T., Maemura, K., & Ohtsuka, T. (2024). A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis. Colorectal Disease, 26(4), 754-759. https://doi.org/10.1111/codi.16880
Vancouver
Mori S, Kita Y, Baba K, Tanabe K, Wada M, Yoshino S, et al. A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis. Colorectal Disease. 2024;26(4):754-759. doi:10.1111/codi.16880
BibTeX
@article{Mori2024,
author = {Mori, Shinichiro and Kita, Yoshiaki and Baba, Kenji and Tanabe, Kan and Wada, Masumi and Yoshino, Shunichiro and Nishida, Nanako and Iino, Satoshi and Setoyama, Tetsuro and Maemura, Kosei and Ohtsuka, Takao},
title = {A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis},
journal = {Colorectal Disease},
year = {2024},
volume = {26},
number = {4},
pages = {754--759},
doi = {10.1111/codi.16880}
}
EUVIMED