A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis

Shinichiro Mori, Yoshiaki Kita, Kenji Baba, Kan Tanabe, Masumi Wada, Shunichiro Yoshino, Nanako Nishida, Satoshi Iino, Tetsuro Setoyama, Kosei Maemura, Takao Ohtsuka

Colorectal Disease · 2024-04 · 26 (4) · 754-759

DOI: 10.1111/codi.16880 ↗

Kurz gefasst

Video/Audio in der Zeitschrift Colorectal Disease, online erschienen am 05.03.2024. Verfasst von Shinichiro Mori und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Digestive Surgery, Kagoshima City Hospital, Kagoshima, Japan. Hauptthemen laut MEDLINE: Colectomy, Anastomosis, Surgical, Robotic Surgical Procedures, Absorbable Implants. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA.

Method

The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material.

Results

This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228–459 min), 12 min (range 11–17 min), 10 mL (range 0–110 mL), and 10 days (range 8–15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications.

Conclusion

The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColectomyAnastomosis, SurgicalRobotic Surgical ProceduresAbsorbable ImplantsColonic NeoplasmsIleumSurgical StaplersHumansMaleFemaleMiddle AgedAgedSutureless Surgical ProceduresOperative TimeColonTreatment OutcomeSurgical StaplingAdultLength of Stay

Stichwörter der Autor:innen

intracorporeal anastomosislinear stapleroverlapped anastomosisreinforced bioabsorbable materialrobotic colectomy

Autor:innen und Institutionen

  • Department of Digestive Surgery, Kagoshima City Hospital, Kagoshima, Japan.
  • Department of Digestive Surgery, Graduate School of Medicine, Kagoshima University, Kagoshima, Japan.

Zitieren

APA

Mori, S., Kita, Y., Baba, K., Tanabe, K., Wada, M., Yoshino, S., Nishida, N., Iino, S., Setoyama, T., Maemura, K., & Ohtsuka, T. (2024). A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis. Colorectal Disease, 26(4), 754-759. https://doi.org/10.1111/codi.16880

Vancouver

Mori S, Kita Y, Baba K, Tanabe K, Wada M, Yoshino S, et al. A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis. Colorectal Disease. 2024;26(4):754-759. doi:10.1111/codi.16880

BibTeX
@article{Mori2024,
  author = {Mori, Shinichiro and Kita, Yoshiaki and Baba, Kenji and Tanabe, Kan and Wada, Masumi and Yoshino, Shunichiro and Nishida, Nanako and Iino, Satoshi and Setoyama, Tetsuro and Maemura, Kosei and Ohtsuka, Takao},
  title = {A sutureless overlapped anastomosis technique using linear staplers with reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis},
  journal = {Colorectal Disease},
  year = {2024},
  volume = {26},
  number = {4},
  pages = {754--759},
  doi = {10.1111/codi.16880}
}
Kostenlos starten →